对于恶性胸膜间皮瘤,在保留肺的半胸胸膜调强放射治疗后,心脏剂量测定与放射性肺炎风险相关。

Heart Dosimetry is Correlated With Risk of Radiation Pneumonitis After Lung-Sparing Hemithoracic Pleural Intensity Modulated Radiation Therapy for Malignant Pleural Mesothelioma.

作者信息

Yorke Ellen D, Jackson Andrew, Kuo Li Cheng, Ojo Anthonia, Panchoo Kelly, Adusumilli Prasad, Zauderer Marjorie G, Rusch Valerie W, Shepherd Annemarie, Rimner Andreas

机构信息

Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York.

Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York.

出版信息

Int J Radiat Oncol Biol Phys. 2017 Sep 1;99(1):61-69. doi: 10.1016/j.ijrobp.2017.04.025. Epub 2017 Apr 27.

Abstract

PURPOSE

To determine clinically helpful dose-volume and clinical metrics correlating with symptomatic radiation pneumonitis (RP) in malignant pleural mesothelioma (MPM) patients with 2 lungs treated with hemithoracic intensity modulated pleural radiation therapy (IMPRINT).

METHODS AND MATERIALS

Treatment plans and resulting normal organ dose-volume histograms of 103 consecutive MPM patients treated with IMPRINT (February 2005 to January 2015) to the highest dose ≤50.4 Gy satisfying departmental normal tissue constraints were uniformly recalculated. Patient records provided maximum RP grade (Common Terminology Criteria for Toxicity and Adverse Event version 4.0) and clinical and demographic information. Correlations analyzed with the Cox model were grade ≥2 RP (RP2+) and grade ≥3 RP (RP3+) with clinical variables, with volumes of planning target volume (PTV) and PTV-lung overlap and with mean dose, percent volume receiving dose D (V), highest dose encompassing % volume V, (D), and heart, total, ipsilateral, and contralateral lung volumes.

RESULTS

Twenty-seven patients had RP2+ (14 with RP3+). The median prescription dose was 46.8 Gy (39.6-50.4 Gy, 1.8 Gy/fraction). The median age was 67.6 years (range, 42-83 years). There were 79 men, 40 never-smokers, and 44 with left-sided MPM. There were no significant (P≤.05) correlations with clinical variables, prescription dose, total lung dose-volume metrics, and PTV-lung overlap volume. Dose-volume correlations for heart were RP2+ with V (35 ≤ D ≤ 47 Gy, V strongest at P=.003), RP3+ with V (31 ≤ D ≤ 45 Gy), RP2+ with D (5 ≤ V ≤ 30%), RP3+ with D (15 ≤ V ≤ 35%), and mean dose. Significant for ipsilateral lung were RP2+ with V (38 ≤ D ≤ 44 Gy), RP3+ with V, RP2+ and RP3+ with minimum dose, and for contralateral lung, RP2+ with maximum dose. Correlation of PTV with RP2+ was strong (P<.001) and also significant with RP3+.

CONCLUSIONS

Heart dose correlated strongly with symptomatic RP in this large cohort of MPM patients with 2 lungs treated with IMPRINT. Planning constraints to reduce future heart doses are suggested.

摘要

目的

确定在接受半胸强度调制胸膜放射治疗(IMPRINT)的双侧肺癌恶性胸膜间皮瘤(MPM)患者中,与症状性放射性肺炎(RP)相关的临床有用剂量体积和临床指标。

方法和材料

对2005年2月至2015年1月期间连续103例接受IMPRINT治疗且最高剂量≤50.4 Gy并满足科室正常组织限制的MPM患者的治疗计划和由此产生的正常器官剂量体积直方图进行统一重新计算。患者记录提供了最大RP分级(毒性和不良事件通用术语标准第4.0版)以及临床和人口统计学信息。使用Cox模型分析的相关性包括≥2级RP(RP2 +)和≥3级RP(RP3 +)与临床变量、计划靶体积(PTV)和PTV-肺重叠体积以及平均剂量、接受剂量D的体积百分比(V)、包含体积V的最高剂量(D)以及心脏、全肺、同侧肺和对侧肺体积之间的相关性。

结果

27例患者发生RP2 +(14例为RP3 +)。中位处方剂量为46.8 Gy(39.6 - 50.4 Gy,1.8 Gy/分次)。中位年龄为67.6岁(范围42 - 83岁)。有79名男性,40名从不吸烟者,44例左侧MPM。与临床变量、处方剂量、全肺剂量体积指标和PTV-肺重叠体积无显著(P≤0.05)相关性。心脏的剂量体积相关性为RP2 +与V(35≤D≤47 Gy,V在P = 0.003时最强)、RP3 +与V(31≤D≤45 Gy)、RP2 +与D(5≤V≤30%)、RP3 +与D(15≤V≤35%)以及平均剂量。同侧肺的显著相关性为RP2 +与V(38≤D≤44 Gy)、RP3 +与V、RP2 +和RP3 +与最小剂量,对侧肺的显著相关性为RP2 +与最大剂量。PTV与RP2 +的相关性很强(P < 0.001),与RP3 +也显著相关。

结论

在这一接受IMPRINT治疗的双侧肺癌MPM患者大队列中,心脏剂量与症状性RP密切相关。建议制定计划限制以降低未来心脏剂量。

相似文献

引用本文的文献

2

本文引用的文献

6
Heart irradiation as a risk factor for radiation pneumonitis.心脏照射作为放射性肺炎的一个危险因素。
Acta Oncol. 2011 Jan;50(1):51-60. doi: 10.3109/0284186X.2010.521192. Epub 2010 Sep 28.
7
Proton therapy for malignant pleural mesothelioma after extrapleural pleuropneumonectomy.胸膜外全肺切除术后恶性胸膜间皮瘤的质子治疗。
Int J Radiat Oncol Biol Phys. 2010 Oct 1;78(2):628-34. doi: 10.1016/j.ijrobp.2009.11.006. Epub 2010 Apr 10.
8
Radiation dose-volume effects in the lung.肺部的放射剂量-体积效应。
Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S70-6. doi: 10.1016/j.ijrobp.2009.06.091.
10
The impact of heart irradiation on dose-volume effects in the rat lung.心脏照射对大鼠肺部剂量-体积效应的影响。
Int J Radiat Oncol Biol Phys. 2007 Oct 1;69(2):552-9. doi: 10.1016/j.ijrobp.2007.05.065.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验