Suppr超能文献

使用ESAR假脚的膝下截肢者步态中健全侧关节接触力。

Sound side joint contact forces in below knee amputee gait with an ESAR prosthetic foot.

作者信息

Karimi Mohammad Taghi, Salami Firooz, Esrafilian Amir, Heitzmann Daniel W W, Alimusaj Merkur, Putz Cornelia, Wolf Sebastian I

机构信息

Musculoskeletal Research Center, Isfahan University of Medical Sciences, Isfahan, Iran; Rehabilitation Sciences Research Center, Shiraz University of Medical Sciences, Shiraz Iran.

Clinic for Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany.

出版信息

Gait Posture. 2017 Oct;58:246-251. doi: 10.1016/j.gaitpost.2017.08.007. Epub 2017 Aug 8.

Abstract

The incidence of knee and hip joint osteoarthritis in subjects with below knee amputation (BK) appears significantly higher compared to unimpaired subjects, especially in the intact side. However, it is controversial if constant higher loads on the sound side are one of the major factors for an increased osteoarthritis (OA) incidence in subjects with BK, beside other risk factors, e.g. with respect to metabolism. The aim wasto investigate joint contact forces (JCF) calculated by a musculoskeletal model in the intact side and to compare it with those of unimpaired subjects and to further elucidate in how far increased knee JCF are associated with increased frontal plane knee moments. A group of seven subjects with BK amputation and a group of ten unimpaired subjects were recruited for this study. Gait data were measured by 3D motion capture and force plates. OpenSim software was applied to calculate JCF. Maximum joint angles, ground reaction forces, and moments as well as time distance parameters were determined and compared between groups showing no significant differences, with some JCF components of knee and hip even being slightly smaller in subjects with BK compared to the reference group. This positive finding may be due to the selected ESAR foot. However, other beneficial factors may also have influenced this positive result such as the general good health status of the subjects or the thorough and proper fitting and alignment of the prosthesis.

摘要

与未受损受试者相比,膝下截肢(BK)患者的膝关节和髋关节骨关节炎发病率明显更高,尤其是在未截肢侧。然而,除了其他风险因素(如代谢方面)外,健侧持续承受更高负荷是否是BK患者骨关节炎(OA)发病率增加的主要因素之一,目前仍存在争议。本研究的目的是通过肌肉骨骼模型计算未截肢侧的关节接触力(JCF),并将其与未受损受试者的关节接触力进行比较,以进一步阐明膝关节JCF增加与额面膝关节力矩增加之间的关联程度。本研究招募了一组7名BK截肢患者和一组10名未受损受试者。通过三维运动捕捉和测力板测量步态数据。应用OpenSim软件计算JCF。确定并比较了最大关节角度、地面反作用力、力矩以及时间距离参数,两组之间无显著差异,与参照组相比,BK患者膝关节和髋关节的一些JCF分量甚至略小。这一积极结果可能归因于所选的ESAR足部。然而,其他有益因素也可能对这一积极结果产生了影响,如受试者总体健康状况良好,或假体安装彻底且合适。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验