Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxuexiang, Chengdu, 610041, China.
Department of Clinical Laboratory Medicine, Xijing Hospital, Fourth Military Medical University, No. 15 Changle West Road, Xi'an, 710032, China.
Sci Rep. 2017 Aug 25;7(1):9559. doi: 10.1038/s41598-017-10103-9.
We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent assays, which are commonly used in China. We tested 13,767 serum samples collected from 13 independent laboratories throughout China, which included samples from 999 previously confirmed syphilis cases and 158 'borderline' samples previously identified using the Architect, InTec, and KHB tests. The Mikrogen Syphilis Immunoblot was used to confirm positive test results. The consistency between the four different assays was 100%. The sensitivity of Elecsys immunoassay was 100% versus 98.26% for Architect, 99.11% for InTec; and 98.56% for KHB. The specificity of the Elecsys immunoassay was 99.81% versus 99.74% for Architect; 99.93% versus 99.80% for InTec; and 99.85% versus 99.77% for KHB. For borderline samples, the Elecsys immunoassay yielded no false-negative results and fewer false-positive results, compared to the other tests. Considering the ease-of-use, automation, high speed, and high throughput capacity of the Elecsys assay, the higher sensitivity and specificity indicate it is superior for routine screening of serum samples for syphilis diagnosis.
我们比较了罗氏诊断 Elecsys 免疫分析法检测患者血清样本中梅毒螺旋体特异性抗体的性能,与雅培实验室 Architect 化学发光微粒子免疫分析法以及在中国常用的 InTec 和 KHB 酶联免疫吸附法进行了比较。我们测试了来自中国 13 个独立实验室的 13767 份血清样本,其中包括 999 例先前确诊的梅毒病例和 158 例先前使用 Architect、InTec 和 KHB 测试确定的“边界”样本。Mikrogen 梅毒免疫印迹用于确认阳性测试结果。四种不同检测方法的一致性为 100%。Elecsys 免疫分析法的灵敏度为 100%,与 Architect 的 98.26%、InTec 的 99.11%和 KHB 的 98.56%相比。Elecsys 免疫分析法的特异性为 99.81%,与 Architect 的 99.74%相比;与 InTec 的 99.93%相比;与 KHB 的 99.85%相比。对于边界样本,与其他检测方法相比,Elecsys 免疫分析法没有假阴性结果,假阳性结果更少。考虑到 Elecsys 检测的易用性、自动化、高速和高通量能力,较高的灵敏度和特异性表明,它在常规筛查血清样本用于梅毒诊断方面具有优势。