Suppr超能文献

新型鹰嘴张力钢板是否是鹰嘴骨折张力带钢丝固定的有效替代方法?一项对尸体骨骼的生物力学研究。

Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.

作者信息

Gruszka Dominik, Arand Charlotte, Greenfield Julia, Nowak Tobias E, Kuechle Raphael, Kuhn Sebastian, Rommens Pol M

机构信息

Department of Orthopaedics and Traumatology, University Medical Center of Johannes Gutenberg University, Langenbeckstr. 1, 55131, Mainz, Germany.

GRESPI EA 4694, Faculty of Sport Sciences, University of Reims Champagne-Ardenne, Reims, France.

出版信息

Arch Orthop Trauma Surg. 2017 Dec;137(12):1651-1658. doi: 10.1007/s00402-017-2760-5. Epub 2017 Sep 1.

Abstract

INTRODUCTION

Tension band wiring (TBW) used for olecranon fractures is afflicted with a high rate of complications. The aim of this study was to compare the stability of the TBW versus an alternative, novel low-profile olecranon tension plate (OTP) with angular stable screws in a simulated complex fracture model.

MATERIALS AND METHODS

Nine fresh-frozen pairs of cadaver proximal ulnae with an oblique osteotomy and an additional wedge fragment simulating an unstable fracture were tested. The TBW and OTP were implanted pairwise. The elbow motion was simulated in a single-muscle model and ranged from full extension to 90° of flexion. The pulling force of the triceps tendon ranged from 50 to 200 N. The displacement of the fracture fragments was measured with a video motion analysis system over 304 cycles. Data were assessed statistically using the Wilcoxon signed-rank test.

RESULTS

The cyclic loading tests showed mean loosening of the fracture fragments at the articular surface of 0.56 mm using TBW (SD 0.65) and 0.15 mm for OTP (SD 0.39). There was no statistical significance in loosening between the two constructs (p = 0.31). No plate breakage or screw loosening occurred.

CONCLUSIONS

The low-profile OTP, using the principles of pre-tensioning, lag, cortical, and angular stable screws together, demonstrated similar stability after olecranon fracture fixation when compared with the TBW technique and a lag screw in the olecranon fracture model with a third wedge fragment.

摘要

引言

用于鹰嘴骨折的张力带钢丝固定术(TBW)并发症发生率较高。本研究的目的是在模拟复杂骨折模型中,比较张力带钢丝固定术与另一种新型低轮廓鹰嘴张力钢板(OTP)及角度稳定螺钉的稳定性。

材料与方法

测试9对新鲜冷冻的尸体尺骨近端,尺骨做斜行截骨并附加一个楔形骨折块以模拟不稳定骨折。张力带钢丝固定术和低轮廓鹰嘴张力钢板成对植入。在单肌肉模型中模拟肘关节运动,范围从完全伸展到屈曲90°。肱三头肌腱的拉力范围为50至200 N。通过视频运动分析系统在304个周期内测量骨折块的位移。使用Wilcoxon符号秩检验对数据进行统计学评估。

结果

循环加载试验显示,使用张力带钢丝固定术时骨折块在关节面的平均松动为0.56 mm(标准差0.65),使用低轮廓鹰嘴张力钢板时为0.15 mm(标准差0.39)。两种固定方式在松动方面无统计学意义(p = 0.31)。未发生钢板断裂或螺钉松动。

结论

在带有第三楔形骨折块的鹰嘴骨折模型中,低轮廓鹰嘴张力钢板结合预张力、拉力、皮质骨和角度稳定螺钉的原理,在鹰嘴骨折固定后显示出与张力带钢丝固定术和拉力螺钉相似的稳定性。