Suppr超能文献

颅面部区域运动控制测试组合的心理测量评估

Psychometric evaluation of a motor control test battery of the craniofacial region.

作者信息

von Piekartz H, Stotz E, Both A, Bahn G, Armijo-Olivo S, Ballenberger N

机构信息

Department of Physical Therapy and Rehabilitation, University of Applied Science Osnabrück, Osnabrueck, Germany.

Privat Praxis for Physiotherapy Specialized in Orofacial Pain, Physical Therapy, Graz, Austria.

出版信息

J Oral Rehabil. 2017 Dec;44(12):964-973. doi: 10.1111/joor.12574. Epub 2017 Sep 30.

Abstract

The primary objective of this study was to determine the structural and known-group validity as well as the inter-rater reliability of a test battery to evaluate the motor control of the craniofacial region. Seventy volunteers without TMD and 25 subjects with TMD (Axes I) per the DC/TMD were asked to execute a test battery consisting of eight tests. The tests were video-taped in the same sequence in a standardised manner. Two experienced physical therapists participated in this study as blinded assessors. We used exploratory factor analysis to identify the underlying component structure of the eight tests. Internal consistency (Cronbach's α), inter-rater reliability (intra-class correlation coefficient) and construct validity (ie, hypothesis testing-known-group validity) (receiver operating curves) were also explored for the test battery. The structural validity showed the presence of one factor underlying the construct of the test battery. The internal consistency was excellent (0.90) as well as the inter-rater reliability. All values of reliability were close to 0.9 or above indicating very high inter-rater reliability. The area under the curve (AUC) was 0.93 for rater 1 and 0.94 for rater two, respectively, indicating excellent discrimination between subjects with TMD and healthy controls. The results of the present study support the psychometric properties of test battery to measure motor control of the craniofacial region when evaluated through videotaping. This test battery could be used to differentiate between healthy subjects and subjects with musculoskeletal impairments in the cervical and oro-facial regions. In addition, this test battery could be used to assess the effectiveness of management strategies in the craniofacial region.

摘要

本研究的主要目的是确定一套测试组合的结构效度、已知群组效度以及评分者间信度,以评估颅面部区域的运动控制。根据DC/TMD标准,招募了70名无颞下颌关节紊乱症(TMD)的志愿者和25名患有TMD(轴I)的受试者,要求他们执行一套由八项测试组成的测试组合。测试以标准化方式按相同顺序进行录像。两名经验丰富的物理治疗师作为盲法评估者参与了本研究。我们使用探索性因素分析来确定八项测试的潜在组成结构。还对该测试组合的内部一致性(克朗巴哈α系数)、评分者间信度(组内相关系数)和结构效度(即假设检验——已知群组效度)(接受者操作特征曲线)进行了探索。结构效度表明该测试组合的结构背后存在一个因素。内部一致性良好(0.90),评分者间信度也良好。所有信度值均接近或高于0.9,表明评分者间信度非常高。评分者1的曲线下面积(AUC)为0.93,评分者2的为0.94,分别表明TMD患者与健康对照之间具有出色的区分能力。本研究结果支持通过录像评估时该测试组合在测量颅面部区域运动控制方面的心理测量特性。该测试组合可用于区分健康受试者与颈部和口面部区域有肌肉骨骼损伤的受试者。此外,该测试组合可用于评估颅面部区域管理策略的有效性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验