Suppr超能文献

反应时间中频率依赖性低频波动随时间及跨任务的可重复性。

Reproducibility of frequency-dependent low frequency fluctuations in reaction time over time and across tasks.

作者信息

Liu Zan-Zan, Qu Hui-Jie, Tian Zhuo-Ling, Han Meng-Jian, Fan Yi, Ge Lie-Zhong, Zang Yu-Feng, Zhang Hang

机构信息

Department of Psychology, Zhejiang Sci-Tech University, Hangzhou, China.

Institutes of Psychological Sciences, Hangzhou Normal University, Hangzhou, China.

出版信息

PLoS One. 2017 Sep 14;12(9):e0184476. doi: 10.1371/journal.pone.0184476. eCollection 2017.

Abstract

OBJECTIVE

Increased levels of reaction time variability (RTV) are characteristics of sustained attention deficits. The clinical significance of RTV has been widely recognized. However, the reliability of RTV measurements has not been widely studied. The present study aimed to assess the test-retest reliability of RTV conventional measurements, e.g., the standard deviation (SD), the coefficient of variation (CV), and a new measurement called the amplitude of low frequency fluctuation (ALFF) of RT. In addition, we aimed to assess differences and similarities of these measurements between different tasks.

METHOD

Thirty-seven healthy college students participated in 2 tasks, i.e., an Eriksen flanker task (EFT) and a simple reaction task (SRT), twice over a mean interval of 56 days. Conventional measurements of RTV including RT-SD and RT-CV were assessed first. Then the RT time series were converted into frequency domains, and RT-ALFF was further calculated for the whole frequency band (0.0023-0.167 Hz) and for a few sub-frequency bands including Slow-6 (<0.01 Hz), Slow-5 (0.01-0.027 Hz), Slow-4 (0.027-0.073 Hz), and Slow-3 (0.073-0.167 Hz). The test-retest reliability of these measurements was evaluated through intra-class correlation (ICC) tests. Differences and correlations between each EFT and SRT measurement were further examined during both visits.

RESULTS

  1. The RT-ALFF of the Slow-5/4/3 and conventional measurements of RT-SD and RT-CV showed moderate to high levels of test-retest reliability. EFT RT-ALFF patterns generated slightly higher ICC values than SRT values in higher frequency bands (Slow-3), but SRT RT-ALFF values showed slightly higher ICC values than EFT values in lower frequency bands (Slow-5 and Slow-4). 2) RT-ALFF magnitudes in each sub-frequency band were greater for the SRT than those for the EFT. 3) The RT-ALFF in the Slow-4 of the EFT was found to be correlated with the RT-ALFF in the Slow-5 of the SRT for both two visits, but no consistently significant correlation was found between the same frequency bands.

CONCLUSIONS

These findings reveal good test-retest reliability for conventional measurements and for the RT-ALFF of RTV. The RT-ALFF presented frequency-dependent similarities across tasks. All of our results reveal the presence of different frequency structures between the two tasks, and thus the frequency-dependent characteristics of different tasks deserve more attention in future studies.

摘要

目的

反应时间变异性(RTV)水平升高是持续性注意力缺陷的特征。RTV的临床意义已得到广泛认可。然而,RTV测量的可靠性尚未得到广泛研究。本研究旨在评估RTV传统测量方法的重测信度,例如标准差(SD)、变异系数(CV)以及一种名为反应时间低频波动幅度(ALFF)的新测量方法。此外,我们旨在评估这些测量方法在不同任务之间的差异和相似性。

方法

37名健康大学生参与了两项任务,即埃里克森侧翼任务(EFT)和简单反应任务(SRT),平均间隔56天进行两次测试。首先评估RTV的传统测量方法,包括反应时间标准差(RT-SD)和反应时间变异系数(RT-CV)。然后将反应时间序列转换到频域,进一步计算全频段(0.0023 - 0.167 Hz)以及几个子频段(包括慢波6(<0.01 Hz)、慢波5(0.01 - 0.027 Hz)、慢波4(0.027 - 0.073 Hz)和慢波3(0.073 - 0.167 Hz))的反应时间ALFF。通过组内相关系数(ICC)测试评估这些测量方法的重测信度。在两次测试期间,进一步检查每个EFT和SRT测量之间的差异和相关性。

结果

1)慢波5/4/3的反应时间ALFF以及反应时间标准差和反应时间变异系数的传统测量方法显示出中等到高水平的重测信度。在较高频段(慢波3),EFT反应时间ALFF模式产生的ICC值略高于SRT值,但在较低频段(慢波5和慢波4),SRT反应时间ALFF值显示出略高于EFT值的ICC值。2)每个子频段的SRT反应时间ALFF幅度均大于EFT。3)在两次测试中均发现,EFT慢波4中的反应时间ALFF与SRT慢波5中的反应时间ALFF相关,但在相同频段之间未发现始终显著的相关性。

结论

这些发现揭示了传统测量方法以及RTV的反应时间ALFF具有良好的重测信度。反应时间ALFF在不同任务之间呈现出频率依赖性的相似性。我们所有的结果都揭示了两项任务之间存在不同的频率结构,因此不同任务的频率依赖性特征在未来研究中值得更多关注。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a2d2/5598978/4743dd9e6c14/pone.0184476.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验