Cheng Qiaoyuan, Shou Linjun, Chen Cen, Shi Shi, Zhou Minghao
Zhejiang Institute for Food and Drug Control, Hangzhou, Zhejiang, 310052, PR China.
Zhejiang University of Technology, Hangzhou, Zhejiang, 31000, PR China.
J Chromatogr B Analyt Technol Biomed Life Sci. 2017 Oct 1;1064:92-99. doi: 10.1016/j.jchromb.2017.09.009. Epub 2017 Sep 9.
In this paper, an ultra-high-performance liquid chromatography coupled with linear ion trap quadrupole Orbitrap high resolution mass spectrometry (UHPLC-LTQ-Orbitrap HRMS) method was developed and validated for identification, confirmation and quantitation of illegal adulterated weight-loss drugs in plant dietary supplements. 13 wt-loss drugs were well separated by the gradient elution of 10mmol/L ammonium acetate - 0.05% formic acid HO and acetonitrile at a flow rate of 0.2mL/min within 12min. The MS analysis was operated under the positive ion and in full MS/dd-MS (data-dependent MS) mode. The full MS scan with resolution at 60 000 FWHM and narrow mass windows at 5ppm acquired data for identification and quantitation, and dd-MS scan with resolution at 15 000 FWHM obtained product ions for confirmation. The method validation showed good linearity with coefficients of determination (r) higher than 0.9951 for all analytes. Meantime, all the LOD and LLOQ values were in the respective range of 0.3-2 and 1-9ng/g. The accuracy, intra- and inter-day precision were in the ranges of -1.7 to 3.4%, 1.7-5.0% and 1.9-4.4%, respectively. The mean recoveries ranged from 85.4 to 107.1%, while the absolute and relative matrix effect were in the corresponding range of 98.2-108.6% and 2.6-8.7%. Among 120 batches of weight loss plant dietary supplements, sibutramine and fluoxertine or both were positive in 29 samples. In general, LTQ-Orbitrap HRMS technology was a powerful tool for the analysis of illegal ingredients in dietary supplements.
本文建立并验证了一种超高效液相色谱-线性离子阱四极杆-轨道阱高分辨率质谱联用(UHPLC-LTQ-Orbitrap HRMS)方法,用于鉴定、确认和定量植物性膳食补充剂中非法掺假的减肥药物。13种减肥药物在12分钟内以0.2mL/min的流速,通过10mmol/L醋酸铵-0.05%甲酸水溶液和乙腈的梯度洗脱实现了良好分离。质谱分析在正离子模式和全扫描/数据依赖二级质谱(data-dependent MS)模式下进行。全扫描分辨率为60000 FWHM,质量窗口为5ppm,用于鉴定和定量;二级质谱扫描分辨率为15000 FWHM,用于获得产物离子进行确认。方法验证表明,所有分析物的线性良好,决定系数(r)均高于0.9951。同时,所有检测限和定量限分别在0.3-2ng/g和1-9ng/g范围内。准确度、日内和日间精密度分别在-1.7%至3.4%、1.7%-5.0%和1.9%-4.4%范围内。平均回收率在85.4%至107.1%之间,绝对和相对基质效应分别在98.2%-108.6%和-2.6%-8.7%范围内。在120批次减肥植物性膳食补充剂中,29个样品中含有西布曲明和氟西汀或两者均呈阳性。总体而言,LTQ-Orbitrap HRMS技术是分析膳食补充剂中非法成分的有力工具。