Wang Xiaoxiao, Zeng Lin, Li Gang, Xu Mao, Wei Bin, Li Yan, Li Nan, Tao Liyuan, Zhang Hua, Guo Xiangyang, Zhao Yiming
Research Center of Clinical Epidemiology, Peking University Third Hospital, Beijing, China.
Department of Anesthesiology, Peking University Third Hospital, Beijing, China.
BMJ Open. 2017 Sep 18;7(9):e016316. doi: 10.1136/bmjopen-2017-016316.
This study aims to provide a comprehensive description of noise levels in operating rooms (ORs) in a tertiary care hospital in China. Additionally, the study aims to examine the deviation in noise levels from international and internal standards as well as the differences in noise levels by category of surgery and day of the week.
We monitored noise levels in 23 ORs in a tertiary care hospital in China between August 2015 and March 2016. Dosimeters were used to determine noise levels. The noise data collected in the dosimeter were downloaded to an IBM computer for subsequent analysis. One-way analysis of variance and Student's t-test were used to examine the differences in noise levels.
The noise level in the ORs ranged between 59.2 and 72.3 dB(A), with 100% of the measurements exceeding the recommended hospital noise standards. There was substantial similarity in noise levels from Monday to Friday (F=1.404, p=0.234), with a range between 63.7 and 64.5 dB(A). The difference in noise levels by category of surgery was significant (F=3.381, p<0.001). The results of the post hoc analysis suggested that ophthalmic surgery had significantly higher noise levels than otolaryngological surgery or general surgery.
Ophthalmic surgery had significantly higher noise levels than otolaryngological or general surgeries. High noise levels were identified in all evaluated ORs during weekdays, and these levels consistently exceeded the currently accepted standards. These findings warrant further investigation to determine the harmful effects of noise on both patients and staff in ORs..
本研究旨在全面描述中国一家三级甲等医院手术室的噪声水平。此外,该研究旨在检验噪声水平与国际和国内标准的偏差,以及不同手术类别和一周中不同日期的噪声水平差异。
我们于2015年8月至2016年3月期间,对中国一家三级甲等医院的23间手术室的噪声水平进行了监测。使用剂量计来测定噪声水平。剂量计收集的噪声数据被下载到一台IBM计算机上以便后续分析。采用单因素方差分析和学生t检验来检验噪声水平的差异。
手术室的噪声水平在59.2至72.3dB(A)之间,100%的测量值超过了推荐的医院噪声标准。周一至周五的噪声水平有很大的相似性(F=1.404,p=0.234),范围在63.7至64.5dB(A)之间。不同手术类别的噪声水平差异显著(F=3.381,p<0.001)。事后分析结果表明,眼科手术的噪声水平显著高于耳鼻喉科手术或普通外科手术。
眼科手术的噪声水平显著高于耳鼻喉科手术或普通外科手术。工作日期间,在所有评估的手术室中都发现了高噪声水平,并且这些水平一直超过目前公认的标准。这些发现值得进一步研究,以确定噪声对手术室患者和工作人员的有害影响。