Suppr超能文献

身体肥胖指数在确定哥伦比亚超重或肥胖成年人身体脂肪百分比中的作用。

The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity.

作者信息

Ramírez-Vélez Robinson, Correa-Bautista Jorge Enrique, González-Ruíz Katherine, Tordecilla-Sanders Alejandra, García-Hermoso Antonio, Schmidt-RioValle Jacqueline, González-Jiménez Emilio

机构信息

Centro de Estudios para la Medición de la Actividad Física (CEMA), Escuela de Medicina y Ciencias de la Salud, Universidad del Rosario, Bogotá, DC 111221, Colombia.

Grupo de Ejercicio Físico y Deportes, Vicerrectoría de Investigaciones, Universidad Manuela Beltrán, Bogotá, DC 110231, Colombia.

出版信息

Int J Environ Res Public Health. 2017 Sep 21;14(10):1093. doi: 10.3390/ijerph14101093.

Abstract

The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson's correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample -test, Lin's concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was = 0.885, < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin's concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (-5.6 (95%CI -6.4 to -4.8); < 0.001). In the women, these differences were (-3.6 (95%CI -4.7 to -2.5); < 0.001). Overall, the bias of the BAI-BF% was -4.8 ± 3.2 BF%; < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups.

摘要

本研究的目的是调查身体脂肪率指数(BAI)作为一种便捷工具,通过生物电阻抗分析(BIA)评估超重/肥胖成年人样本中体脂百分比(BF%)的准确性。研究人群由96名志愿者组成(60%为女性,平均年龄40.6±7.5岁)。评估了人体测量特征(体重指数、身高、腰高比、臀围和腰围)、社会经济状况和饮食,并通过BIA-BF%和BAI-BF%测量BF%。在控制潜在混杂因素的同时,使用Pearson相关系数评估BAI-BF%与通过BIA-BF%评估的BF%之间的相关性。通过配对样本t检验、Lin一致性相关系数和Bland-Altman图分析获得两种方法测量的BF%之间的一致性。总体而言,在调整潜在混杂因素(年龄、社会经济状况和饮食)后,通过BIA-BF%获得的BF%与通过BAI-BF%估计的BF%之间的相关性为r = 0.885,P < 0.001。Lin一致性相关系数在两性中均为中等。在男性中,配对t检验显示两种方法之间的BF%存在显著平均差异(-5.6(95%CI -6.4至-4.8);P < 0.001)。在女性中,这些差异为(-3.6(95%CI -4.7至-2.5);P < 0.001)。总体而言,BAI-BF%的偏差为-4.8±3.2 BF%(P < 0.001),表明与参考方法相比,BAI-BF%方法显著低估了BF%。在超重/肥胖成年人中,BAI与通过BIA-BF%测量的BF%一致性较低;因此,我们得出结论,当体脂百分比水平较低或较高时,BIA-BF%在两性中均不准确。需要进一步研究以在不同种族群体中证实我们的发现。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e845/5664594/54c3f38604e3/ijerph-14-01093-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验