Suppr超能文献

一种用于膀胱癌监测的新型基于mRNA的尿液检测方法准确性提高。

Increased accuracy of a novel mRNA-based urine test for bladder cancer surveillance.

作者信息

Pichler Renate, Fritz Josef, Tulchiner Gennadi, Klinglmair Gerald, Soleiman Afschin, Horninger Wolfgang, Klocker Helmut, Heidegger Isabel

机构信息

Department of Urology, Medical University Innsbruck, Innsbruck, Austria.

Department of Medical Statistics, Informatics and Health Economics, Medical University Innsbruck, Innsbruck, Austria.

出版信息

BJU Int. 2018 Jan;121(1):29-37. doi: 10.1111/bju.14019. Epub 2017 Oct 12.

Abstract

OBJECTIVES

To evaluate the diagnostic accuracy of the Xpert Bladder Cancer (BC) Monitor, compared with cystoscopy and cytology in the oncological follow-up of non-muscle-invasive bladder cancer (NMIBC).

MATERIAL AND METHODS

A total of 140 patients with a history of NMIBC undergoing routine surveillance at our institution were enrolled prospectively in this study (ISRCTN study registry number 37210907). Urine cytology was evaluated according to the Paris classification system. In addition, urinary specimens were analysed using the Xpert BC Monitor, which measures five target mRNAs (ABL1, CRH, IGF2, UPK1B, ANXA10) using real-time PCR. Descriptive analysis, diagnostic accuracy including sensitivity, specificity, positive (PPV) and negative predictive value (NPV), receiver-operating characteristic curve, and area under the curve (AUC) were calculated.

RESULTS

The overall sensitivity (0.84) and NPV (0.93) of the Xpert BC Monitor were significantly superior to those of bladder washing cytology (0.33 and 0.76; P < 0.001). Subgroup analyses confirmed the high sensitivity of the Xpert BC Monitor even in low-grade (0.77) and pTa (0.82) disease compared with barbotage cytology (low-grade: 0.13; pTa: 0.21). The overall specificity of the Xpert BC Monitor and barbotage cytology was similar (0.91 vs 0.94; P = 0.41). Combining the Xpert BC Monitor with barbotage cytology (AUC = 0.85) did not enhance diagnostic performance compared with the performance of the Xpert BC Monitor alone (AUC = 0.87).

CONCLUSION

In this study, we report for the first time that the Xpert BC Monitor, a new mRNA-based urine test, outperforms cytology with regard to sensitivity and NPV, even in low-grade and pTa tumours, with no reduction of specificity.

摘要

目的

在非肌层浸润性膀胱癌(NMIBC)的肿瘤学随访中,评估Xpert膀胱癌(BC)监测仪与膀胱镜检查及细胞学检查相比的诊断准确性。

材料与方法

本研究前瞻性纳入了在我院接受常规监测的140例有NMIBC病史的患者(ISRCTN研究注册号37210907)。根据巴黎分类系统评估尿液细胞学。此外,使用Xpert BC监测仪分析尿液样本,该监测仪通过实时PCR测量5种靶标mRNA(ABL1、CRH、IGF2、UPK1B、ANXA10)。计算描述性分析、包括敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)的诊断准确性、受试者操作特征曲线以及曲线下面积(AUC)。

结果

Xpert BC监测仪的总体敏感性(0.84)和NPV(0.93)显著优于膀胱冲洗细胞学检查(0.33和0.76;P<0.001)。亚组分析证实,与灌洗细胞学检查相比(低级别:0.13;pTa:0.21),即使在低级别(0.77)和pTa期(0.82)疾病中,Xpert BC监测仪也具有高敏感性。Xpert BC监测仪和灌洗细胞学检查的总体特异性相似(0.91对0.94;P = 0.41)。与单独使用Xpert BC监测仪的性能(AUC = 0.87)相比,将Xpert BC监测仪与灌洗细胞学检查相结合(AUC = 0.85)并未提高诊断性能。

结论

在本研究中,我们首次报告,新型基于mRNA的尿液检测Xpert BC监测仪在敏感性和NPV方面优于细胞学检查,即使在低级别和pTa期肿瘤中也是如此,且特异性未降低。