Suppr超能文献

一种用于同时定量测定血浆中15种抗生素的简单超高效液相色谱-高分辨率质谱分析法。

A simple ultra-high-performance liquid chromatography-high resolution mass spectrometry assay for the simultaneous quantification of 15 antibiotics in plasma.

作者信息

Lefeuvre S, Bois-Maublanc J, Hocqueloux L, Bret L, Francia T, Eleout-Da Violante C, Billaud E M, Barbier F, Got L

机构信息

Laboratory of Biochemistry, CHR Orléans, France.

Laboratory of Biochemistry, CHR Orléans, France.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2017 Oct 15;1065-1066:50-58. doi: 10.1016/j.jchromb.2017.09.014. Epub 2017 Sep 11.

Abstract

Antibiotic (ATB) treatment of critically ill patients with pathophysiological injuries remains a challenge due to the constant increase in antimicrobial resistance. Therapeutic drug monitoring (TDM) is advised for ATB dose adjustments to avoid suboptimal concentrations and dose-related adverse effects. Therefore, a single and reliable analytical method for a broad selection of ATBs was developed using a high-resolution mass spectrometry (HRMS) platform for frequent use in intensive care units. An UHPLC assay coupled to high resolution accurate mass acquisition has been developed for the quantification of penicillins (amoxicillin, oxacillin, piperacillin, and ticarcillin), cephalosporines (cefepime, cefotaxime, ceftazidime, and ceftriaxone), carbapenems (ertapenem, imipenem, and meropenem), lincosamide (clindamycin), quinolones (ofloxacin and ciprofloxacin) and tazobactam. Plasma samples (100μL) were spiked with an internal standard solution followed by protein precipitation. Separation was achieved on an Accucore C18 column, which enabled sample analysis every 9min. All compounds were detected in electrospray positive ion mode and quantified with a linear regression between 0.5 and 32mg/L (r2>0.998). Overall precision and accuracy did not exceed 15%. No significant matrix effect was observed for the studied ATBs. Stored stock solutions at -20°C were stable for 6 months, except for amoxicillin and imipenem. Analytes in plasma were stable for 24h under ambient conditions as well as in post-preparation in an autosampler, except for amoxicillin and imipenem. This HRMS assay provides the simultaneous quantification of 15 ATB; it fulfills the usual quality criteria and was successfully applied for routine TDM of ATBs. The method is based on a full scan acquisition, and it would be easy to add other compounds to the present panel in the future, as this assay has already been proven to be efficient for different classes of compounds.

摘要

由于抗菌药物耐药性不断增加,对抗患有病理生理损伤的重症患者进行抗生素(ATB)治疗仍然是一项挑战。建议进行治疗药物监测(TDM)以调整ATB剂量,避免浓度不足和剂量相关的不良反应。因此,利用高分辨率质谱(HRMS)平台开发了一种单一且可靠的分析方法,用于广泛选择的ATB,以便在重症监护病房中频繁使用。已开发出一种超高效液相色谱(UHPLC)测定法,结合高分辨率精确质量采集,用于定量青霉素(阿莫西林、苯唑西林、哌拉西林和替卡西林)、头孢菌素(头孢吡肟、头孢噻肟、头孢他啶和头孢曲松)、碳青霉烯类(厄他培南、亚胺培南和美罗培南)、林可酰胺类(克林霉素)、喹诺酮类(氧氟沙星和环丙沙星)以及他唑巴坦。将血浆样品(100μL)与内标溶液混合,然后进行蛋白沉淀。在Accucore C18柱上实现分离,每9分钟可进行一次样品分析。所有化合物均在电喷雾正离子模式下检测,并通过0.5至32mg/L之间的线性回归进行定量(r2>0.998)。总体精密度和准确度不超过15%。对于所研究的ATB,未观察到明显的基质效应。除阿莫西林和亚胺培南外,储存在-20°C的储备溶液在6个月内稳定。血浆中的分析物在环境条件下以及在自动进样器中制备后24小时内稳定,阿莫西林和亚胺培南除外。这种HRMS测定法可同时定量15种ATB;它符合通常的质量标准,并已成功应用于ATB的常规TDM。该方法基于全扫描采集,将来很容易在当前检测项目中添加其他化合物,因为该测定法已被证明对不同类别的化合物有效。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验