Suppr超能文献

液相色谱-串联质谱法测定人全血和尿液中 52 种抗生素及其在法医案例中的应用。

Liquid chromatography with tandem mass spectrometric method for determination of 52 antibiotics in human whole blood and urine and application to forensic cases.

机构信息

School of Forensic Medicine, Shanxi Medical University, Taiyuan, 030001, China.

Shanxi Key Laboratory of Forensic Medicine, Shanxi, 030600, China.

出版信息

Forensic Toxicol. 2024 Jul;42(2):202-211. doi: 10.1007/s11419-024-00688-y. Epub 2024 Apr 20.

Abstract

PURPOSE

A rapid and reliable method was developed and validated for the simultaneous analysis of 52 antibiotics (cephalosporins, penicillins, carbapenems, lincosamides, quinolones, nitroimidazoles, macrolides, sulfonamides, tetracyclines, glycopeptide) in urine and whole blood by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

METHOD

Analytes were extracted by dilution or protein precipitation and analyzed on an Agilent 1260 HPLC system coupled to an Agilent 6470 Triple Quadrupole Mass Spectrometer.

RESULTS

The method attended method validation criteria. The limits of detection were equal or lower than 2.0 ng/mL, whereas the limits of quantification ranged from 0.1 to 10.0 ng/mL, from 0.1 to 5.0 ng/mL, in urine and whole blood, respectively. For all analytes, the bias and intra- and inter-day precision values were less than 14.7%. The ranges of recovery values of all antibiotics were 76.5-124.5% in whole blood and 76.3-121.8% in urine, values of the effects were lower than 25% in two matrices. No evidence of carryover was observed. The study of sample stability showed that almost all analytes were stable at 24 °C for 24 h, all analytes were stable at -20 °C for 14 days and at -80 °C for 30 days. Freeze-thaw cycles stability showed that antibiotics were stable except for imipenem. Autosampler stability study showed that all analytes were stable for 24 h, except for imipenem and amoxicillin. Applicability was proven by analyzing authentic whole blood (n = 86) and urine (n = 79) samples from patients under antibiotics treatment. Therefore, this method was applied to the analysis 3 forensic allergy cases, which were positive for at least one analyte.

CONCLUSIONS

A simple, sensitive and high-throughput method for the simultaneous determination of different classes of antibiotics in urine and whole blood samples was developed and applied. This sensitive method was successfully applied to forensic cases.

摘要

目的

建立并验证了一种同时测定尿液和全血中 52 种抗生素(头孢菌素类、青霉素类、碳青霉烯类、林可酰胺类、喹诺酮类、硝基咪唑类、大环内酯类、磺胺类、四环素类、糖肽类)的高效液相色谱-串联质谱(HPLC-MS/MS)分析方法。

方法

采用稀释或蛋白沉淀法提取分析物,在安捷伦 1260 HPLC 系统上与安捷伦 6470 三重四极杆质谱仪联用进行分析。

结果

该方法符合方法验证标准。检测限均等于或低于 2.0ng/mL,而定量限分别为 0.110.0ng/mL 和 0.15.0ng/mL,在尿液和全血中。对于所有分析物,偏倚和日内及日间精密度值均小于 14.7%。所有抗生素的回收率范围在全血中为 76.5%124.5%,在尿液中为 76.3%121.8%,两种基质中的效应值均低于 25%。未观察到交叉污染。样品稳定性研究表明,几乎所有分析物在 24°C 下 24 小时内稳定,所有分析物在-20°C 下 14 天和-80°C 下 30 天内稳定。冻融循环稳定性研究表明,除亚胺培南外,抗生素均稳定。自动进样器稳定性研究表明,除亚胺培南和阿莫西林外,所有分析物在 24 小时内均稳定。通过分析 86 例接受抗生素治疗的患者的真实全血(n=86)和尿液(n=79)样本,证明了该方法的适用性。因此,该方法被应用于分析 3 例法医过敏案例,这些案例中至少有 1 种分析物呈阳性。

结论

建立了一种简单、灵敏、高通量的同时测定尿液和全血样品中不同类别抗生素的方法,并将其应用于实际样品中。该灵敏方法成功应用于法医案例。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验