Li Bing, Chen Li, Chen Yihui, Lu Jiajun, Liu Hao, Liu Yu, Yao Panpan, Liu Rui, Sheng Minjie
Department of Ophthalmology, Yangpu Hospital, Tongji University School of MedicineShanghai 200090, China.
Department of Ophthalmology, Shanghai Tenth Hospital, Tongji University School of MedicineShanghai 200072, China.
Am J Transl Res. 2017 Sep 15;9(9):4104-4110. eCollection 2017.
In this study, we aimed to provide a new method of corneal preservation by injecting DisCoVisc into the anterior chamber of eyeballs and evaluate its efficiency for corneal transplantation.
Three pairs of eyeballs (n=6) were preserved by DisCoVisc viscoelastic agent, and the corneas were stored for 1 to 6 days. Then, the structure and morphology of cornea were analyzed by hematoxylin-eosin (H&E) staining, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, and transmission electron microscopy (TEM). The corneas preserved by this method were transplanted into 15 patients with corneal disease and the efficacy was assessed.
Epithelial cells and endothelial cells were intact and a normal morphology was preserved in both fresh corneas and corneas stored for 1-6 days by DisCoVisc viscoelastic agent. Corneal endothelial cells did not appear apoptosis in fresh corneas and corneas stored for 1-3 days, whereas a few apoptosis positive cells were shown on the 4 day. The results of TEM showed that all corneas had active corneal endothelial cells with normal nuclei and homogenous nucleoplasm. Desmosomes and hemidesmosomes were closely connected. Mild nuclear pyknosis and autophagic cell death were only found from the 6 day, and mitochondria appeared a little bubble from the 5 day. Visual acuity in 11 of the 15 patients receiving transplantation of the preserved corneas was improved by more than 0.5. Average corneal endothelial cell counts, areas of corneal endothelial cells, and CV% of average area were not affected during the 6-month follow-up. Compared to the values obtained one-month postoperatively, the values of corneal thickness were significantly reduced in the three-month and six-month periods.
Corneal preservation technology with the injection of DisCoVisc viscoelastic agent may effectively extend the preservation time of corneas for five days, which could be used for patients as penetrating keratoplasty surgery.
在本研究中,我们旨在通过向眼球前房注射DisCoVisc提供一种新的角膜保存方法,并评估其在角膜移植中的有效性。
用DisCoVisc粘弹性剂保存三对眼球(n = 6),角膜保存1至6天。然后,通过苏木精 - 伊红(H&E)染色、末端脱氧核苷酸转移酶dUTP缺口末端标记(TUNEL)染色和透射电子显微镜(TEM)分析角膜的结构和形态。将用该方法保存的角膜移植到15例角膜疾病患者中并评估疗效。
新鲜角膜和用DisCoVisc粘弹性剂保存1 - 6天的角膜中,上皮细胞和内皮细胞均完整,形态正常。新鲜角膜和保存1 - 3天的角膜中角膜内皮细胞未出现凋亡,而在第4天出现少数凋亡阳性细胞。TEM结果显示,所有角膜的角膜内皮细胞均活跃,细胞核正常,核质均匀。桥粒和半桥粒紧密连接。仅在第6天发现轻度核固缩和自噬性细胞死亡,从第5天开始线粒体出现少许空泡。接受保存角膜移植的15例患者中有11例视力提高超过0.5。在6个月的随访期间,平均角膜内皮细胞计数、角膜内皮细胞面积和平均面积的CV%均未受影响。与术后1个月获得的值相比,在3个月和6个月时角膜厚度值显著降低。
注射DisCoVisc粘弹性剂的角膜保存技术可有效延长角膜保存时间达5天,可用于穿透性角膜移植手术患者。