Akmalov A E, Chistyakov A A, Kotkovskii G E, Martynov I L, Spitsin E M
1 Micro- and Nanosystems Department, National Research Nuclear University, Moscow Engineering Physics Institute, Moscow, Russia.
2 Lab.990, Stelmakh Research Institute "Polyus", Moscow, Russia.
Eur J Mass Spectrom (Chichester). 2017 Aug;23(4):140-145. doi: 10.1177/1469066717721696.
The paper presents the results of research and development of ion mobility spectrometer with laser ion sources for detecting ultra-low quantities of explosives in air. Particular attention is paid to the mechanisms of the formation of negative ions. It is shown that laser ionization with respect to ion mobility spectrometry provides an increase of sensitivity and selectivity of detection. The ion mobility spectra of the most common nitro explosives are investigated. The detection threshold for laser ion mobility spectrometer was reached at the level of 10g/cm (for trinitrotoluene).
本文介绍了用于检测空气中超低含量爆炸物的带有激光离子源的离子迁移谱仪的研发成果。特别关注负离子的形成机制。结果表明,激光电离对于离子迁移谱法而言可提高检测的灵敏度和选择性。研究了最常见的硝基炸药的离子迁移谱。激光离子迁移谱仪的检测阈值达到了10μg/cm³(对于三硝基甲苯)。