Annu Int Conf IEEE Eng Med Biol Soc. 2017 Jul;2017:2177-2180. doi: 10.1109/EMBC.2017.8037286.
Electrical stimulation therapy (EST) of lower esophageal sphincters (LES) is a new technique for the treatment of gastroesophageal reflux disease (GERD). In this paper, an implantable LES stimulator with wireless power transmission is proposed for the treatment of GERD. The LES stimulator is composed of an implantable pulse generator (IPG), an external controller, and a wireless power transmission module. The IPG, whose area is 31×21 mm, is designed to generate voltage-regulated constant-current stimulation pulses. The external controller allows for wireless programming of the IPG via a Bluetooth Low Energy (BLE) module. The wireless power transmission module provides power for the IPG. According to the measurement of output stimulus waveforms, the proposed LES stimulator is capable of delivering electrical stimulations with a current ranging between 0 and 8 mA. To evaluate the safety and efficacy of the proposed LES stimulator, experiments were performed on 12 male New Zealand white rabbits. Esophageal manometry was performed before and after the procedure and the LES pressure (LESP) has been recorded. The mean LESP is increased significantly in the stimulation group than the sham group (stimulation group: 9.25±1.24 mmHg vs 13.99 ±1.28 mmHg, p<;0.05; sham group: 9.00±1.22 mmHg vs 9.23±1.27 mmHg, p=0.267). The results show that the electrical stimulation delivered by the LES stimulator can safely and effectively increase resting LES pressure in acute animal models, suggesting that the implantable LES stimulator is a perspective approach for treating GERD in clinics.
下食管括约肌(LES)的电刺激疗法(EST)是一种治疗胃食管反流病(GERD)的新技术。本文提出了一种用于治疗GERD的具有无线电力传输功能的可植入LES刺激器。该LES刺激器由一个可植入脉冲发生器(IPG)、一个外部控制器和一个无线电力传输模块组成。IPG的面积为31×21毫米,设计用于产生电压调节的恒流刺激脉冲。外部控制器允许通过低功耗蓝牙(BLE)模块对IPG进行无线编程。无线电力传输模块为IPG提供电力。根据输出刺激波形的测量,所提出的LES刺激器能够提供电流范围在0至8毫安之间的电刺激。为了评估所提出的LES刺激器的安全性和有效性,对12只雄性新西兰白兔进行了实验。在手术前后进行了食管测压,并记录了LES压力(LESP)。刺激组的平均LESP比假手术组显著增加(刺激组:9.25±1.24毫米汞柱对13.99±1.28毫米汞柱,p<0.05;假手术组:9.00±1.22毫米汞柱对9.23±1.27毫米汞柱,p = 0.267)。结果表明,LES刺激器提供的电刺激可以在急性动物模型中安全有效地增加静息LES压力,这表明可植入LES刺激器是临床上治疗GERD的一种有前景的方法。