Suppr超能文献

通过声学语音分析检测误吸引起的声音变化。

Detection of voice changes due to aspiration via acoustic voice analysis.

作者信息

Kang Young Ae, Kim Jaeock, Jee Sung Ju, Jo Cheol Woo, Koo Bon Seok

机构信息

Department of Otolaryngology-Head and Neck Surgery, Republic of Korea.

Major in Speech Pathology Education, Graduate School of Education, Kangnam University, Yongin-si, Republic of Korea.

出版信息

Auris Nasus Larynx. 2018 Aug;45(4):801-806. doi: 10.1016/j.anl.2017.10.007. Epub 2017 Oct 31.

Abstract

OBJECTIVE

Aspiration can occur during swallowing. The present study investigated the feasibility of identifying aspiration risk (AR) via acoustic voice parameters.

MATERIALS AND METHODS

In total, 165 patients scheduled for a videofluoroscopic swallowing study (VFSS) were included. The patients were divided into two groups (AR and non-AR) based on their VFSS results. The AR group, which had ingested materials on or below the vocal folds, included 59 patients (42 males and 17 females). The non-AR group, which showed normal swallowing, included 106 patients (49 males and 57 females). The major cause of swallowing disorders was a stroke. A sustained vowel/a/for at least 3s was recorded before and after swallowing. Eight acoustic voice parameters were measured using PRAAT, including fundamental frequency, standard deviation of F0, jitter, relative average perturbation (RAP), shimmer, amplitude perturbation quotient (APQ), harmonic-to-noise ratio (HNR), and noise-to-harmonic ratio (NHR). Changes in each acoustic voice parameter before and after the VFSS were compared between the two groups with a repeated-measures mixed analysis of variance.

RESULTS

Only RAP showed a statistically significant interaction between group (non-AR and AR) and time (pre- and post-swallowing; p=0.030). RAP decreased after swallowing in the AR group; however, it increased in the non-AR group. Jitter and NHR increased in the non-AR group but decreased in the AR group after swallowing, but the difference was not statistically significant.

CONCLUSIONS

Our results suggest that the accumulation of pasty food in the vocal folds may modify vocal fold vibration and change voice quality in patients with penetration/aspiration. Several acoustic voice parameters, especially jitter, RAP, and NHR, were affected by AR. Thus, acoustic voice analysis may be helpful in making a diagnosis of AR as a supplementary tool for standard swallowing study including VFSS or fiberoptic examination.

摘要

目的

吞咽过程中可能会发生误吸。本研究调查了通过声学语音参数识别误吸风险(AR)的可行性。

材料与方法

总共纳入了165例计划进行视频荧光吞咽造影检查(VFSS)的患者。根据VFSS结果将患者分为两组(AR组和非AR组)。AR组有59例患者(42例男性和17例女性),其声带或声带以下有食物摄入。非AR组有106例患者(49例男性和57例女性),吞咽正常。吞咽障碍的主要原因是中风。在吞咽前后记录至少3秒的持续元音/a/。使用PRAAT测量八个声学语音参数,包括基频、F0的标准差、抖动、相对平均扰动(RAP)、闪烁、幅度扰动商(APQ)、谐波与噪声比(HNR)以及噪声与谐波比(NHR)。两组之间在VFSS前后各声学语音参数的变化采用重复测量混合方差分析进行比较。

结果

只有RAP在组(非AR组和AR组)和时间(吞咽前和吞咽后)之间显示出统计学上的显著交互作用(p = 0.030)。AR组吞咽后RAP降低;然而,非AR组吞咽后RAP升高。非AR组吞咽后抖动和NHR增加,而AR组吞咽后抖动和NHR降低,但差异无统计学意义。

结论

我们的结果表明,糊状食物在声带中的积聚可能会改变声带振动并改变穿透性/误吸患者的语音质量。几个声学语音参数,尤其是抖动、RAP和NHR,受AR影响。因此,声学语音分析作为标准吞咽研究(包括VFSS或纤维喉镜检查)的辅助工具,可能有助于AR的诊断。