Suppr超能文献

一种改良的快速、简便、廉价、高效、耐用且安全的净化方法,随后采用液相色谱-串联质谱法对面粉中的高氯酸盐、溴酸盐和次磷酸盐进行快速分析。

A modified quick, easy, cheap, effective, rugged, and safe cleanup method followed by liquid chromatography-tandem mass spectrometry for the rapid analysis of perchlorate, bromate and hypophosphite in flour.

作者信息

Xian Yanping, Guo Xindong, Hou Xiangchang, Wang Li, Wu Yuluan, Chen Liwei, Dong Hao, Wang Bin

机构信息

Guangzhou Quality Supervision and Testing Institute, Guangzhou 511447, China.

Guangzhou Quality Supervision and Testing Institute, Guangzhou 511447, China.

出版信息

J Chromatogr A. 2017 Dec 1;1526:31-38. doi: 10.1016/j.chroma.2017.10.047. Epub 2017 Oct 25.

Abstract

A selective, sensitive and useful method, based on modified QuEChERS cleanup combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the negative-ion electrospray ionization (ESI) mode, was developed and validated for the simultaneous determination of three inorganic anions including perchlorate (ClO), bromate (BrO) and hypophosphite (HPO) in flour. The extraction parameters and LC-MS/MS conditions were optimized by single-factor experiment and sorbent combination in modified QuEChERS clean-up was optimized through response surface analysis. Three target analytes were separated on a normal-phase Phenomenex Luna Silica (2) column (150mm×2.0mm, 5μm, 100Å) with the mobile phase of a mixture of 5mmol/L ammonium acetate water solution and acetonitrile, detected by MS/MS under multiple reaction monitoring and quantified by external standard method. The developed method was validated in terms of the sensitivity, linearity, accuracy and precision, and matrix effect. The method showed a good linearity (R>0.999) for all analytes in their respective concentration ranges. The ILOQs and MLOQs for perchlorate, bromate and hypophosphite were 0.1, 0.5, 5.0μg/L and 2.0, 6.0, 60.0μg/L, respectively. The average recoveries of three target analytes from the negative samples spiked at three different concentrations were in a range from 84.6% to 104.9%. The intra-day precision (n=6) and inter-day precision (n=5) of the target analytes were in the ranges of 2.9%-6.9% and 6.4%-8.2%. The matrix effect of this method was observed between 0.83 and 1.17 and was acceptable. The validated method was successfully applied to determine the concentrations of these inorganic anions in flour. Results found that perchlorate and hypophosphite were detected in 33 out of 50 and 7 out of 50 flour samples.

摘要

建立了一种基于改进的QuEChERS净化结合负离子电喷雾电离(ESI)模式下的液相色谱 - 串联质谱(LC-MS/MS)的选择性、灵敏且实用的方法,用于同时测定面粉中的三种无机阴离子,包括高氯酸盐(ClO)、溴酸盐(BrO)和次磷酸盐(HPO)。通过单因素实验优化了萃取参数和LC-MS/MS条件,并通过响应面分析优化了改进的QuEChERS净化中的吸附剂组合。三种目标分析物在正相Phenomenex Luna Silica (2) 柱(150mm×2.0mm,5μm,100Å)上分离,流动相为5mmol/L醋酸铵水溶液和乙腈的混合物,在多反应监测模式下通过MS/MS检测,采用外标法定量。该方法在灵敏度、线性、准确度、精密度和基质效应方面进行了验证。该方法在各自的浓度范围内对所有分析物均显示出良好的线性(R>0.999)。高氯酸盐、溴酸盐和次磷酸盐的仪器检测限(ILOQs)和方法定量限(MLOQs)分别为0.1、0.5、5.0μg/L和2.0、6.0、60.0μg/L。在三种不同浓度加标的阴性样品中,三种目标分析物的平均回收率在84.6%至104.9%之间。目标分析物的日内精密度(n = 6)和日间精密度(n = 5)分别在2.9% - 6.9%和6.4% - 8.2%范围内。该方法的基质效应在0.83至1.17之间,可接受。该验证方法成功应用于测定面粉中这些无机阴离子的浓度。结果发现,50份面粉样品中有33份检测出高氯酸盐,7份检测出次磷酸盐。