Suppr超能文献

反相柱上非水尺寸排阻色谱中的有机溶剂改性剂和温度效应

Organic solvent modifier and temperature effects in non-aqueous size-exclusion chromatography on reversed-phase columns.

作者信息

Caltabiano Anna M, Foley Joe P, Striegel André M

机构信息

Analytical Sciences and Development, GlaxoSmithKline, 1250 S. Collegeville Rd., Collegeville, PA 19426, USA; Department of Chemistry, Drexel University, 3141 Chestnut St., Philadelphia, PA 19104, USA.

Department of Chemistry, Drexel University, 3141 Chestnut St., Philadelphia, PA 19104, USA.

出版信息

J Chromatogr A. 2018 Jan 5;1531:83-103. doi: 10.1016/j.chroma.2017.11.027. Epub 2017 Nov 24.

Abstract

Common reversed-phase columns (C, C, phenyl, and cyano) offer inert surfaces suitable for the analysis of polymers by size-exclusion chromatography (SEC). The effect of tetrahydrofuran (THF) solvent and the mixtures of THF with a variety of common solvents used in high performance liquid chromatography (acetonitrile, methanol, dimethylformamide, 2-propanol, ethanol, acetone and chloroform) on reversed-phase stationary phase characteristics relevant to size exclusion were studied. The effect of solvent on the elution of polystyrene (PS) and poly(methyl methacrylate) (PMMA) and the effect of column temperature (within a relatively narrow range corresponding to typical chromatographic conditions, i.e., 10°C-60°C) on the SEC partition coefficients K of PS and PMMA polymers, were also investigated. The bonded phases show remarkable differences in size separations when binary mixtures of THF with other solvents are used as the mobile phase. The solvent impact can be two-fold: (i) change of the polymeric coil size, and possible shape, and (ii) change of the stationary phase pore volume. If the effect of this impact is properly moderated, then the greatest benefit of optimized solute resolution can be achieved. Additionally, this work provides an insight on solvent-stationary phase interactions and their effects on column pore volume. The only effect of temperature observed in our studies was a decreased elution volume of the polymers with increasing temperature. SEC partition coefficients were temperature-independent in the range of 10°C-60°C and therefore, over this temperature range elution of PS and PMMA polymers is by near-ideal SEC on reversed-phase columns. Non-ideal SEC appears to occur for high molar mass PMMA polymers on a cyano column when alcohols are used as mobile phase modifiers.

摘要

常见的反相柱(C、C、苯基和氰基)提供了惰性表面,适用于通过尺寸排阻色谱法(SEC)分析聚合物。研究了四氢呋喃(THF)溶剂以及THF与高效液相色谱中各种常用溶剂(乙腈、甲醇、二甲基甲酰胺、2-丙醇、乙醇、丙酮和氯仿)的混合物对与尺寸排阻相关的反相固定相特性的影响。还研究了溶剂对聚苯乙烯(PS)和聚甲基丙烯酸甲酯(PMMA)洗脱的影响,以及柱温(在对应于典型色谱条件的相对较窄范围内,即10°C - 60°C)对PS和PMMA聚合物的SEC分配系数K的影响。当使用THF与其他溶剂的二元混合物作为流动相时,键合相在尺寸分离方面表现出显著差异。溶剂的影响可能有两方面:(i)聚合物线团尺寸以及可能形状的变化,以及(ii)固定相孔体积的变化。如果这种影响得到适当调节,那么可以实现优化溶质分离度的最大益处。此外,这项工作深入了解了溶剂 - 固定相相互作用及其对柱孔体积的影响。在我们的研究中观察到的温度的唯一影响是聚合物的洗脱体积随温度升高而降低。在10°C - 60°C范围内,SEC分配系数与温度无关,因此,在这个温度范围内,PS和PMMA聚合物在反相柱上的洗脱是通过近乎理想的SEC进行的。当使用醇类作为流动相改性剂时,对于高摩尔质量的PMMA聚合物在氰基柱上似乎会出现非理想的SEC情况。

相似文献

本文引用的文献

9
Gradient separation of polymers at critical point of adsorption.聚合物在吸附临界点的梯度分离
J Chromatogr A. 2002 Aug 9;966(1-2):25-40. doi: 10.1016/s0021-9673(02)00705-7.
10
Geometry of chemically modified silica.化学改性二氧化硅的几何结构
J Chromatogr A. 2001 Apr 13;913(1-2):49-63. doi: 10.1016/s0021-9673(00)01076-1.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验