Privette T H, Myers R D
Department of Pharmacology, East Carolina University School of Medicine, Greenville, NC 27834.
J Neurosci Methods. 1989 Jan;26(3):195-202. doi: 10.1016/0165-0270(89)90116-7.
The characteristics of performance were compared for two types of pump, peristaltic and infusion-withdrawal, commonly used for localized push-pull perfusion of brain tissue. Guide cannulae were stereotaxically implanted bilaterally in the caudate-putamen complex of the rat at homologous sites in the coronal plane. Consecutive 5.0 min push-pull perfusions were carried out simultaneously with one pump perfusing ipsilaterally while the other pump perfused the contralateral caudate nucleus. 3H-dopamine (DA) diluted with an artificial CSF was used as the radiotracer and was perfused at a rate of 25 microliters/min. Following the collection of 7-8 samples, the brain was fixed, removed, and histological sections taken through the sites of perfusion. Microscopic examination of the perfusion site showed that the circumscribed lesion at the tip of the cannula connected to either pump was generally indistinguishable. A comparison of the values of 3H-DA recovery in samples obtained with the peristaltic and infusion-withdrawal pumps demonstrated that: (1) the respective uptakes of the catecholamine into caudate tissue paralleled one another in most experiments, and (2) the content of 3H-DA in push-pull perfusates recovered from sample to sample varied independently of the pump used. Based on the results of histopathological examination and DA radioactivity values, it is concluded that the peristaltic pump as well as the syringe-driven push-pull pump can yield valid experimental observations which are comparable to one another.
比较了常用于脑组织局部推挽灌注的两种泵(蠕动泵和输注-抽回泵)的性能特征。将引导套管通过立体定位法双侧植入大鼠尾状核-壳核复合体冠状平面的同源部位。连续进行5.0分钟的推挽灌注,同时一个泵向同侧灌注,另一个泵向对侧尾状核灌注。用人工脑脊液稀释的3H-多巴胺(DA)作为放射性示踪剂,以25微升/分钟的速度灌注。收集7-8个样本后,将大脑固定、取出,并在灌注部位制作组织学切片。对灌注部位的显微镜检查表明,连接到任一泵的套管尖端处的局限性病变通常无法区分。对用蠕动泵和输注-抽回泵获得的样本中3H-DA回收率的值进行比较表明:(1)在大多数实验中,儿茶酚胺进入尾状核组织的各自摄取量彼此平行,(2)从一个样本到另一个样本回收的推挽灌注液中3H-DA的含量与所使用的泵无关。基于组织病理学检查结果和DA放射性值,得出结论:蠕动泵以及注射器驱动的推挽泵都能产生相互可比的有效实验观察结果。