We developed a standard reproducible test to determine surgical needle sharpness. This parameter was measured by recording the maximum force required to push a curved surgical needle through a thin laminated synthetic membrane. Three comparable groups of reversed cutting-edge needles were selected from different manufacturers for needle penetration testing. The results of this testing demonstrated that the needle diameter, manufacturing process, and the manufacturer were all important determinants of needle sharpness. Needles with a smaller diameter were sharper than those with a larger diameter. In addition, electrohoned or hand-honed needles were sharper than those subjected to only machine grinding. When comparably sized needles were compared, Ethicon manufactured the sharpest needles, followed by Davis & Geck and Deknatel needles. Scanning electron microscopic photographs and elemental analysis of the surgical needles could be correlated with their sharpness. The sharper needles had long, narrow cutting edge geometries compared with the short wide geometries of duller needles. The sharpest needles were fabricated from an American Society for Testing and Materials (ASTM) 45500 stainless steel alloy that has stronger tensile and yield strengths than those of ASTM 42000 and 42020 alloys used in the creation of the other needles. This stronger alloy allows the manufacturer to produce a longer, narrower cutting point geometry with reduced danger of either bending or breakage during surgery compared with needles made from weaker alloys (ASTM 42000 and ASTM 42020), which accounts for the superior sharpness of the Ethicon surgical needles.

摘要

我们开发了一种标准的可重复测试方法来确定手术缝合针的锋利度。该参数通过记录将弯曲的手术缝合针推过一层薄的复合合成膜所需的最大力来测量。从不同制造商处选取了三组可比的反向刃口缝合针进行针穿透测试。测试结果表明,针的直径、制造工艺和制造商都是针锋利度的重要决定因素。直径较小的针比直径较大的针更锋利。此外,经过电解珩磨或手工珩磨的针比仅经过机器磨削的针更锋利。当比较尺寸相当的针时,Ethicon生产的针最锋利,其次是Davis & Geck和Deknatel的针。手术缝合针的扫描电子显微镜照片和元素分析可以与其锋利度相关联。与钝针短而宽的几何形状相比,更锋利的针具有长而窄的刃口几何形状。最锋利的针由美国材料与试验协会(ASTM)45500不锈钢合金制成,其抗拉强度和屈服强度比用于制造其他针的ASTM 42000和42020合金更强。与由较弱合金(ASTM 42000和ASTM 42020)制成的针相比,这种更强的合金使制造商能够生产出更长、更窄的切割点几何形状,在手术过程中弯曲或断裂的危险更小,这就是Ethicon手术缝合针具有卓越锋利度的原因。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验