Suppr超能文献

一项前瞻性队列研究评估了回收的美学正畸弓丝的外观。

A prospective cohort study assessing the appearance of retrieved aesthetic orthodontic archwires.

机构信息

Barts and The London School of Medicine and Dentistry, London, UK.

University of Bern, Bern, Switzerland.

出版信息

Orthod Craniofac Res. 2018 Feb;21(1):27-32. doi: 10.1111/ocr.12207. Epub 2017 Dec 4.

Abstract

OBJECTIVES

To investigate the appearance of three esthetic nickel titanium (NiTi) wires after 6 weeks of intra-oral cycling and to determine the association between objective and subjective measures of esthetics.

SETTING AND SAMPLE POPULATION

A prospective cohort study was undertaken involving participants undergoing upper fixed orthodontic appliance treatment with ceramic brackets.

MATERIALS AND METHODS

Fifty participants were assigned to one of three groups of NiTi esthetic wires (American Orthodontics Ever White™, Forestadent Biocosmetic™ and GAC High Aesthetic™), with wires retrieved after 6 weeks in situ. Participants completed a bespoke questionnaire exploring perceptions of wire esthetics. Objective measurement of coating loss was undertaken using a custom arch wire jig.

RESULTS

American Orthodontics Ever White™ had the greatest mean coating loss (50.7%) followed by Forestadent Biocosmetic™ (6%), with GAC High Aesthetic TM undergoing minimal loss (0.07%) (P < .001). The majority of coating loss with the American Orthodontics Ever White™ wires arose in the anterior region while Forestadent Biocosmetic™ wires and GAC High Aesthetic™ wires exhibited coating loss posteriorly (P < .001). These findings were reflected in the subjective assessment with a negative correlation found between coating loss and final Visual Analogue Scale scores (P < .001).

CONCLUSIONS

Considerable esthetic variation between arch wires following 6 weeks of intraoral cycling was identified in this prospective cohort study. Intraoral cycling has a negative impact on participant perception of arch wire esthetics, and objective and subjective assessment of wire esthetics appears to be consistent.

摘要

目的

研究三种美学镍钛(NiTi)丝在口腔内循环 6 周后的外观,并确定美学客观和主观测量之间的关系。

设置和样本人群

进行了一项前瞻性队列研究,涉及接受上固定正畸矫治器治疗的陶瓷托槽的参与者。

材料和方法

将 50 名参与者分为三组美学 NiTi 丝(美国 Orthodontics Ever White™、Forestadent Biocosmetic™和 GAC High Aesthetic™),6 周后在原位取出丝。参与者完成了一项专门探索丝美观感的调查问卷。使用定制的弓丝夹具进行涂层损失的客观测量。

结果

美国 Orthodontics Ever White™的平均涂层损失最大(50.7%),其次是 Forestadent Biocosmetic™(6%),GAC High Aesthetic™的损失最小(0.07%)(P <.001)。美国 Orthodontics Ever White™丝的大部分涂层损失发生在前部,而 Forestadent Biocosmetic™丝和 GAC High Aesthetic™丝在后部出现涂层损失(P <.001)。这些发现反映在主观评估中,涂层损失与最终视觉模拟量表评分之间存在负相关(P <.001)。

结论

在这项前瞻性队列研究中,口腔内循环 6 周后发现弓丝之间存在相当大的美观差异。口腔内循环对参与者对弓丝美观的感知有负面影响,并且对丝美观的客观和主观评估似乎是一致的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验