Suppr超能文献

成人呼吸窘迫综合征(ARDS)相关肺毛细血管蛋白渗漏的肺闪烁显像诊断准确性的决定因素:技术说明

Determinants of diagnostic accuracy in pulmonary scintigraphy for pulmonary capillary protein leak associated with adult respiratory distress syndrome (ARDS): a technical note.

作者信息

Tatum J, Sugerman H, Perdikaris N, Rehr R, Burke T, Fratkin M

机构信息

Department of Radiology, Virginia Commonwealth University, Medical College of Virginia, Richmond 23298-0001.

出版信息

Eur J Nucl Med. 1989;15(2):67-70. doi: 10.1007/BF00702621.

Abstract

Radionuclide assessment of pulmonary capillary protein leak using [99mTc] human serum albumin (99mTc-HSA) was first reported from our laboratory. In this study we investigated the impact of 1) sampling time post tracer injection, and 2) lung region assignment, on diagnostic accuracy between 2 groups (control n = 20 and ARDS n = 20). Each patient received 370 MBq 99mTc-HSA i.v. and was imaged for 45 min. The slope index (SI) [change in lung: heart activity ratio/min] was calculated from 11 computer assigned lung regions for intervals of 5-15 (early [E]) and 15-45 (late [L]) min. The diagnostic accuracy of E vs L SI calculations for the 11 regions was evaluated by stepwise logistic regression. E SI data and L SI data from the lower 1/3 of the lung did not achieve significance for inclusion in the discriminant model (P less than 0.05). In the nine remaining regions L SI was significant. Optimal discrimination was achieved from L SI data obtained from a region confined to the lateral half of the mid 3rd of the lung field (sensitivity 81%, specificity 85%, accuracy 83%). The results confirm that: 1) a late (15-45 min) sampling period and 2) proper region assignment are necessary to maximize accuracy of this technique.

摘要

我们实验室首次报道了使用[99mTc]人血清白蛋白(99mTc-HSA)对肺毛细血管蛋白渗漏进行放射性核素评估。在本研究中,我们调查了1)示踪剂注射后的采样时间,以及2)肺区域划分,对两组(对照组n = 20,急性呼吸窘迫综合征组n = 20)诊断准确性的影响。每位患者静脉注射370 MBq 99mTc-HSA,并进行45分钟的成像。斜率指数(SI)[肺与心脏活性比的变化/分钟]是根据11个计算机指定的肺区域计算得出的,时间间隔为5 - 15分钟(早期[E])和15 - 45分钟(晚期[L])。通过逐步逻辑回归评估11个区域的E与L SI计算的诊断准确性。来自肺下1/3的E SI数据和L SI数据在纳入判别模型时未达到显著水平(P小于0.05)。在其余九个区域,L SI具有显著性。从局限于肺野中1/3外侧半部分区域获得的L SI数据实现了最佳判别(敏感性81%,特异性85%,准确性83%)。结果证实:1)晚期(15 - 45分钟)采样期和2)适当的区域划分对于最大化该技术的准确性是必要的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验