Suppr超能文献

三维有限元分析在上颌后牙区莫氏锥度种植体上的固位系统与夹板固定

Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis.

作者信息

Lemos Cleidiel Aparecido Araujo, Verri Fellippo Ramos, Santiago Joel Ferreira, Almeida Daniel Augusto de Faria, Batista Victor Eduardo de Souza, Noritomi Pedro Yoshito, Pellizzer Duardo Piza

机构信息

Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Universidade Estadual Paulista, Araçatuba, SP, Brazil.

Department of Health Sciences, University of Sacred Heart, USC - Universidade do Sagrado Coração, Bauru, SP, Brazil.

出版信息

Braz Dent J. 2018 Jan-Feb;29(1):30-35. doi: 10.1590/0103-6440201801492.

Abstract

The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.

摘要

本研究的目的是通过三维(3D)有限元分析,评估固定种植体支持修复体的不同固位系统(粘结或螺丝固位)和牙冠设计(非联冠或联冠)在种植体/部件和骨组织中的应力分布情况。使用InVesalius、Rhinoceros 3D和SolidWorks软件模拟了四个3D模型。模型采用上颌后牙区的III类骨制成。模型包括三个不同长度的直径4.0毫米的莫氏锥度(MT)种植体,其上支持金属烤瓷牙冠。使用Femap和NeiNastran软件对模型进行处理,施加400 N的轴向力和200 N的斜向力。结果以冯·米塞斯应力和最大主应力(σmax)进行可视化显示。在轴向加载下,固位系统和联冠之间种植体/部件的应力分布没有差异;然而,在斜向加载下,粘结式修复体的应力分布比螺丝固位式修复体更好,而联冠倾向于降低第一磨牙种植体中的应力。在轴向和斜向加载下,粘结式修复体在骨组织中的应力分布比螺丝固位式修复体更好。联冠设计仅对螺丝固位式修复体有影响,对粘结式修复体没有影响。MT种植体上的粘结式修复体在种植体/部件和骨组织中显示出更有利的应力分布。仅在斜向加载下,联冠对螺丝固位式修复体的应力分布有利。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验