Suppr超能文献

不同种植体取模技术的准确性:新型托盘设计理念的评估。

Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.

机构信息

Melbourne Dental School, Melbourne University, Carlton, Victoria, Australia.

出版信息

J Prosthodont. 2019 Feb;28(2):e682-e687. doi: 10.1111/jopr.12733. Epub 2017 Dec 29.

Abstract

PURPOSE

To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation.

MATERIALS AND METHODS

A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain.

RESULTS

A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques.

CONCLUSIONS

The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined.

摘要

目的

评估一种新托盘设计概念在 2 种植体情况下与非夹板和夹板印模技术相比的种植体印模准确性。

材料和方法

制作了一个参考棒钛框架,以适合 2 个平行种植体。该框架用于生成具有 2 个种植体的树脂主模型,该种植体与框架精确贴合。评估了三种印模技术:(1)非夹板,(2)夹板和(3)非夹板的改良托盘印模。所有托盘均由光固化丙烯酸树脂材料制成,具有与种植体印模套管相对应的开口。每种技术使用聚(乙烯基硅氧烷)印模材料进行 10 次印模。用 IV 型牙科石膏对印模进行浇铸,生成测试模型。在框架的中间粘合了一个玫瑰应变计。随着每个测试模型上的框架固定螺丝拧紧,记录下产生的应变,直到拧紧至 35 Ncm 完成。使用玫瑰应变计产生的应变来计算最大主应变。

结果

观察到不同印模技术之间存在统计学上的显著差异。改良托盘设计印模技术与最小的框架应变相关,这表明与其他技术相比具有更高的准确性。夹板和非夹板印模技术之间没有显著差异。

结论

新托盘设计概念似乎比其他技术产生更准确的种植体印模。尽管印模技术之间存在统计学差异,但这种差异的临床意义尚待确定。