Suppr超能文献

托普康频域光学相干断层扫描技术测量近视患者视乳头周围视网膜神经纤维层厚度

Peripapillary Retinal Nerve Fiber Layer (RNFL) Thickness Measurements by Topcon SD-OCT in Myopic Patients.

作者信息

Akhtar Nadia, Kausar Ayisha, Afzal Farooq, Ali Syed Khalid, Hamid Nida

机构信息

Department of Ophthalmology, Federal General Hospital, Islamabad.

Department of Ophthalmology, Shifa International Hospital, Islamabad.

出版信息

J Coll Physicians Surg Pak. 2018 Jan;28(1):26-30. doi: 10.29271/jcpsp.2018.01.26.

Abstract

OBJECTIVE

To evaluate the effect of low-to-moderate myopia on peripapillary retinal nerve fiber layer (RNFL) thickness measured by Topcon SD optical coherence tomography (OCT).

STUDY DESIGN

Cross-sectional study.

PLACE AND DURATION OF STUDY

Ophthalmology Department, Shifa Foundation Falahee Clinic, over a period of one year starting from June 2015.

METHODOLOGY

A total of 43 eyes of 43 patients, having mild to moderate myopic refractive error, were enrolled in the study. Refractive error/spherical equivalent was calculated. RNFL thickness was obtained from all four peripapillary quadrants: temporal, superior, nasal, and inferior; and 12 sub-quadrants using Topcon SD OCT. Pearson correlation coefficients (r) were calculated to evaluate relationships between the RNFL thickness and spherical equivalent (SE) before and after adjustment for ocular magnification.

RESULTS

The study included 51.2% females and 48.8% males. Mean age was 30.9 ±6.45 years. Mean axial length was 24.25 ±0.91 mm. Mean SE was -3.25 ±1.93 DS. Mean of average RNFL thickness (with Littmann's correction) was 97.28 ±8.15 µm. Correlation analysis among all subjects showed that the average, mean nasal quadrant, upper nasal, and inferonasal sub-quadrant RNFL thickness had positive correlation with spherical equivalent (r = 0.31, p = 0.045).However, correction of the magnification effect by applying Littmann formula eliminated this effect.

CONCLUSION

In low-to-moderate myopia, RNFL measurements vary with refractive error of the eye. Since ocular magnification significantly affects the RNFL measurement, it should be considered in diagnosing glaucoma.

摘要

目的

评估低度至中度近视对使用拓普康SD光学相干断层扫描(OCT)测量的视乳头周围视网膜神经纤维层(RNFL)厚度的影响。

研究设计

横断面研究。

研究地点和时间

从2015年6月开始,为期一年,在法希法基金会法拉希诊所眼科进行。

方法

本研究共纳入43例患者的43只眼,这些患者有轻度至中度近视屈光不正。计算屈光不正/球镜等效度。使用拓普康SD OCT从视乳头周围的四个象限(颞侧、上方、鼻侧和下方)以及12个子象限获取RNFL厚度。计算Pearson相关系数(r),以评估在调整眼放大率前后RNFL厚度与球镜等效度(SE)之间的关系。

结果

该研究包括51.2%的女性和48.8%的男性。平均年龄为30.9±6.45岁。平均眼轴长度为24.25±0.91mm。平均SE为-3.25±1.93DS。平均平均RNFL厚度(采用利特曼校正)为97.28±8.15µm。所有受试者的相关性分析表明,平均、平均鼻侧象限、鼻上和鼻下子象限的RNFL厚度与球镜等效度呈正相关(r = 0.31,p = 0.045)。然而,应用利特曼公式校正放大效应消除了这种影响。

结论

在低度至中度近视中,RNFL测量值随眼睛的屈光不正而变化。由于眼放大率显著影响RNFL测量,因此在诊断青光眼时应予以考虑。