Suppr超能文献

用于复发性前列腺癌成像的F-氟西克洛维PET的贝叶斯惩罚似然重建(Q.Clear):半定量和临床评估。

Bayesian penalised likelihood reconstruction (Q.Clear) of F-fluciclovine PET for imaging of recurrent prostate cancer: semi-quantitative and clinical evaluation.

作者信息

Teoh Eugene J, McGowan Daniel R, Schuster David M, Tsakok Maria T, Gleeson Fergus V, Bradley Kevin M

机构信息

1 Department of Radiology, Churchill Hospital, Oxford University Hospitals NHS Trust , Oxford , UK.

2 Department of Oncology, University of Oxford , Oxford , UK.

出版信息

Br J Radiol. 2018 May;91(1085):20170727. doi: 10.1259/bjr.20170727. Epub 2018 Jan 22.

Abstract

OBJECTIVE

F-Fluciclovine (FACBC) is an amino acid PET radiotracer approved for recurrent prostate cancer imaging. We investigate the use of Bayesian penalised likelihood (BPL) reconstruction for F-fluciclovine PET.

METHODS

15 F-fluciclovine scans were reconstructed using ordered subset expectation maximisation (OSEM), OSEM + point spread function (PSF) modelling and BPL using β-values 100-600. Lesion maximum standardised uptake value (SUV), organ SUV and standard deviation were measured. Deidentified reconstructions (OSEM, PSF, BPL using β200-600) from 10 cases were visually analysed by two readers who indicated their most and least preferred reconstructions, and scored overall image quality, noise level, background marrow image quality and lesion conspicuity.

RESULTS

Comparing BPL to OSEM, there were significant increments in lesion SUV and signal-to-background up to β400, with highest gain in β100 reconstructions (mean ΔSUV 3.9, p < 0.0001). Organ noise levels increased on PSF, β100 and β200 reconstructions. Across BPL reconstructions, there was incremental reduction in organ noise with increasing β, statistically significant beyond β300-500 (organ-dependent). Comparing with OSEM and PSF, lesion signal-to-noise was significantly increased in BPL reconstructions where β ≥ 300 and  ≥ 200 respectively. On visual analysis, β 300 had the first and second highest scores for image quality, β500 and β600 equal highest scores for marrow image quality and least noise, PSF and β 200 had first and second highest scores for lesion conspicuity. For overall preference, one reader preferred β 300 in 9/10 cases and the other preferred β 200 in all cases.

CONCLUSION

BPL reconstruction of F-fluciclovine PET images improves signal-to-noise ratio, affirmed by overall reader preferences. On balance, β300 is suggested for F-fluciclovine whole body PET image reconstruction using BPL. Advances in knowledge: The optimum β is different to that previously published for F-fluorodeoxyglucose, and has practical implications for a relatively new tracer in an environment with modern reconstruction technologies.

摘要

目的

F-氟西克洛维(FACBC)是一种已被批准用于复发性前列腺癌成像的氨基酸PET放射性示踪剂。我们研究了贝叶斯惩罚似然(BPL)重建在F-氟西克洛维PET中的应用。

方法

使用有序子集期望最大化(OSEM)、OSEM + 点扩散函数(PSF)建模以及β值为100 - 600的BPL对15次F-氟西克洛维扫描进行重建。测量病变最大标准化摄取值(SUV)、器官SUV和标准差。由两位阅片者对来自10例病例的去识别重建图像(OSEM、PSF、β值为200 - 600的BPL)进行视觉分析,阅片者指出他们最喜欢和最不喜欢的重建图像,并对整体图像质量、噪声水平、背景骨髓图像质量和病变清晰度进行评分。

结果

将BPL与OSEM进行比较,在β值达到400时,病变SUV和信号背景比有显著增加,β值为100时重建图像增益最高(平均ΔSUV为3.9,p < 0.0001)。PSF、β值为100和β值为200的重建图像中器官噪声水平增加。在所有BPL重建图像中,随着β值增加,器官噪声逐渐降低,在β值超过300 - 500时具有统计学意义(取决于器官)。与OSEM和PSF相比,在β值分别≥300和≥200的BPL重建图像中,病变信噪比显著增加。在视觉分析中,β值为300的图像质量得分第一和第二高,β值为500和β值为600的骨髓图像质量得分并列最高且噪声最小,PSF和β值为200的病变清晰度得分第一和第二高。对于整体偏好,一位阅片者在9/10的病例中更喜欢β值为300的图像,另一位阅片者在所有病例中都更喜欢β值为200的图像。

结论

F-氟西克洛维PET图像的BPL重建提高了信噪比,这得到了阅片者整体偏好的证实。总体而言,建议使用β值为300进行F-氟西克洛维全身PET图像的BPL重建。知识进展:最佳β值与先前发表的F-氟脱氧葡萄糖的β值不同,并且对于在现代重建技术环境下的一种相对较新的示踪剂具有实际意义。