完全螺纹实心皮质骨螺钉与部分螺纹空心松质骨螺钉固定治疗Lisfranc损伤的生物力学比较

Biomechanical Comparison of Fully Threaded Solid Cortical Versus Partially Threaded Cannulated Cancellous Screw Fixation for Lisfranc Injuries.

作者信息

Rozell Joshua C, Chin Matthew, Donegan Derek J, Hast Michael W

出版信息

Orthopedics. 2018 Mar 1;41(2):e222-e227. doi: 10.3928/01477447-20180103-03. Epub 2018 Jan 9.

Abstract

There currently exists an array of operative strategies to manage Lisfranc injuries. Modular fixation systems present surgeons with a choice between fully threaded solid cortical (FSC) and partially threaded cannulated cancellous (PCC) bone screws when using a transarticular screw approach. It is currently unknown how screw design influences fixation strength in Lisfranc reconstructions. The purpose of this study was to evaluate the biomechanical differences of FSC and PCC screws using a cadaveric model of a simulated Lisfranc injury and controlled benchtop experiments. Ten matched pairs of cadaveric feet received an acute Lisfranc injury and were repaired with FSC or PCC screws. Diastasis was measured between the medial and intermediate cuneiforms and the first and second metatarsals during simulations of partial weight bearing. Three-point bending and axial pull-out tests were performed to characterize screw mechanics that could not be measured within the cadaveric model. Screw design did not affect cuneiform or metatarsal diastasis. Neither screw loosening nor deformation was observed following cadaveric testing. Bending tests indicated FSC screws had higher ultimate strength, but there was no significant difference in yield load. Partially threaded cannulated cancellous bone screws exhibited superior axial pull-out strength. Fully threaded solid cortical and PCC screws provide equal amounts of fixation strength during partial weight bearing and similar resistance to deformation under bending loads. Partially threaded cannulated cancellous screws may simplify the operative procedure and minimize nonoptimal screw placement. If a clinician so desires, PCC screws may be used in lieu of FSC screws without sacrificing fixation strength. [Orthopedics. 2018; 41(2):e222-e227.].

摘要

目前存在一系列用于处理Lisfranc损伤的手术策略。当采用经关节螺钉入路时,模块化固定系统为外科医生提供了全螺纹实心皮质骨(FSC)螺钉和部分螺纹空心松质骨(PCC)螺钉之间的选择。目前尚不清楚螺钉设计如何影响Lisfranc重建中的固定强度。本研究的目的是使用模拟Lisfranc损伤的尸体模型和受控的台式实验来评估FSC和PCC螺钉的生物力学差异。十对匹配的尸体足接受急性Lisfranc损伤,并用FSC或PCC螺钉修复。在部分负重模拟过程中,测量内侧和中间楔骨以及第一和第二跖骨之间的分离情况。进行三点弯曲和轴向拔出试验,以表征尸体模型中无法测量的螺钉力学性能。螺钉设计不影响楔骨或跖骨分离。尸体测试后未观察到螺钉松动或变形。弯曲试验表明FSC螺钉具有更高的极限强度,但屈服载荷没有显著差异。部分螺纹空心松质骨螺钉表现出 superior轴向拔出强度。全螺纹实心皮质骨螺钉和PCC螺钉在部分负重期间提供等量的固定强度,并且在弯曲载荷下具有相似的抗变形能力。部分螺纹空心松质骨螺钉可能会简化手术过程并最大限度地减少非最佳螺钉置入。如果临床医生愿意,可以使用PCC螺钉代替FSC螺钉而不牺牲固定强度。[《骨科》。2018年;41(2):e222 - e227。] (注:superior这里可能是“更好的”意思,原文似乎表述有误,推测是想表达“更好的轴向拔出强度”)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验