采用新型快速、简便、廉价、有效、耐用和安全的固相萃取方法结合 UHPLC-MS/MS 测定饲料中的辛弗林。

Determination of synephrine in feeds by a novel quick, easy, cheap, effective, rugged, and safe solid-phase extraction method combined with UHPLC-MS/MS.

机构信息

Institute of Quality Standards & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, China.

Key Laboratory of Agri-food Quality and Safety, Ministry of Agriculture, Beijing, China.

出版信息

J Sep Sci. 2018 Apr;41(8):1743-1751. doi: 10.1002/jssc.201701194. Epub 2018 Feb 6.

Abstract

To detect and quantify synephrine in feed, an effective analytical method based on quick, easy, cheap, effective, rugged, and safe solid-phase extraction coupled to ultra high performance liquid chromatography with tandem mass spectrometry was developed with isotopic internal standards. Pretreatment was performed using quick, easy, cheap, effective, rugged, and safe solid-phase extraction with primary secondary amine and C18 sorbent as sorbents in combination with Oasis MCX column clean-up to extract and purify feed samples. Tandem mass spectrometry detection in positive ion mode was conducted in positive multiple reaction monitoring mode in addition to the quantitative internal standard method. Two transitions of synephrine at m/z 168.1/150.0 and 168.1/135.0 were selected, and m/z 168.1/135.0 was determined as the quantification ion pair. D -Terbutaline was selected as an internal standard, for which m/z 235.1/153.0 was selected as the quantification ion pair. Good linearity was shown for synephrine in the range of 0.5-50 μg/L, and the correlation coefficient exceeded 0.999. The recoveries in three different feed samples at three spiked levels were 81.42-112.08%, and the relative standard deviations were not greater than 14.66%. The method proposed in this study was reliable and highly effective, and its sensitivity, accuracy, and precision are suitable for determining synephrine residues in feed samples.

摘要

为了检测和定量饲料中的辛弗林,开发了一种基于快速、简便、廉价、有效、耐用和安全的固相萃取与串联质谱联用的同位素内标分析方法。采用丙基乙二胺和 C18 吸附剂作为吸附剂的快速、简便、廉价、有效、耐用和安全固相萃取,结合 Oasis MCX 柱净化,对饲料样品进行提取和纯化。串联质谱检测采用正离子模式,除定量内标法外,还采用正多重反应监测模式进行检测。选择辛弗林的两个跃迁 m/z 168.1/150.0 和 168.1/135.0,并将 m/z 168.1/135.0 确定为定量离子对。选择 D-特布他林作为内标,选择 m/z 235.1/153.0 作为定量离子对。辛弗林在 0.5-50μg/L 范围内呈良好线性,相关系数超过 0.999。在三个不同的饲料样品中,三个添加水平的回收率为 81.42-112.08%,相对标准偏差不大于 14.66%。本研究提出的方法可靠高效,其灵敏度、准确性和精密度适用于饲料样品中辛弗林残留的测定。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验