Görgülü Tahsin
1 Bulent Ecevit University, Zonguldak, Turkey.
Surg Innov. 2018 Apr;25(2):110-114. doi: 10.1177/1553350617752238. Epub 2018 Jan 12.
Preoperative planning is an essential prerequisite for the success of plastic surgery. In procedures such as breast reduction, freehand drawings may be associated with a number of challenges during the determination of axes vertical and parallel to the surgical site. Furthermore, many procedures involve subjective maneuvers, such as attempts aimed at positioning both nipples on the same line and transferring nipple-areola complexes in a well-matched manner. Our newly designed instrument, that is, the goniometer (TG), aims to ensure metric measurements appropriate for the axes, and it may also be used in circumstances that require angle measurements. Moreover, it incorporates a canal system to facilitate surgical designing of the area, to which the nipple-areola complex will be transferred.
From April 2013 to September 2015, TG device was used in superior pedicle breast reduction operation of 96 patients and 50 of them were randomly selected for the purpose of study analyses. An additional randomly selected 50 patients, in whom surgical planning was based on conventional techniques were served as controls. At postoperative 1 year, symmetry analysis was carried out on patient photographs.
No partial or total necrosis occurred at the nipple-areola complex, and symmetrical volume and shape could be achieved in all cases. TG device exhibited superiority in all criteria used for postoperative symmetry analyses (P < .05).
We believe that this device may effectively accelerate the planning process in various types of plastic and aesthetic operations and may help ensure symmetry, especially in reduction mammoplasty and mastopexy.
术前规划是整形手术成功的重要前提。在诸如乳房缩小术等手术中,徒手绘图在确定垂直和平行于手术部位的轴线时可能会面临诸多挑战。此外,许多手术涉及主观操作,例如试图将两个乳头置于同一条线上以及以匹配良好的方式转移乳头乳晕复合体。我们新设计的仪器,即量角器(TG),旨在确保对轴线进行合适的度量测量,并且它也可用于需要角度测量的情况。此外,它包含一个管道系统,以方便对乳头乳晕复合体将要转移到的区域进行手术设计。
2013年4月至2015年9月,TG设备用于96例患者的上蒂乳房缩小术,其中随机选择50例进行研究分析。另外随机选择50例基于传统技术进行手术规划的患者作为对照。术后1年,对患者照片进行对称性分析。
乳头乳晕复合体未发生部分或全部坏死,所有病例均能实现对称的体积和形状。TG设备在用于术后对称性分析的所有标准中均表现出优越性(P <.05)。
我们认为该设备可有效加速各类整形和美容手术的规划过程,并有助于确保对称性,尤其是在乳房缩小术和乳房悬吊术中。