Schnider Nicole, Forrer Fiona Alena, Brägger Urs, Hicklin Stefan Paul
Int J Oral Maxillofac Implants. 2018 Jan/Feb;33(1):188-196. doi: 10.11607/jomi.5929.
The aim of this study was to evaluate the clinical performance of one-piece, screw-retained implant crowns based on hand-veneered computer-aided design/computer-aided manufacture (CAD/CAM) zirconium dioxide abutments with a crossfit connection at least 1 year after insertion of the crown.
Consecutive patients who had received at least one Straumann bone level implant and one-piece, screw-retained implant crowns fabricated with CARES zirconium dioxide abutments were reexamined. Patient satisfaction, occlusal and peri-implant parameters, mechanical and biologic complications, radiologic parameters, and esthetics were recorded.
A total of 50 implant crowns in the anterior and premolar region were examined in 41 patients. The follow-up period of the definitive reconstructions ranged from 1.1 to 3.8 years. No technical and no biologic complications had occurred. At the reexamination, 100% of the implants and reconstructions were in situ. Radiographic evaluation revealed a mean distance from the implant shoulder to the first visible bone-to-implant contact of 0.06 mm at the follow-up examination.
Screw-retained crowns based on veneered CAD/CAM zirconium dioxide abutments with a crossfit connection seem to be a promising way to replace missing teeth in the anterior and premolar region. In the short term, neither failures of components nor complications were noted, and the clinical and radiographic data revealed stable hard and soft tissue conditions.
本研究的目的是评估基于手工贴面的计算机辅助设计/计算机辅助制造(CAD/CAM)二氧化锆基台且具有十字扣连接的一体式螺丝固位种植体牙冠在植入牙冠至少1年后的临床性能。
对连续接受至少一枚士卓曼骨水平种植体以及用CARES二氧化锆基台制作的一体式螺丝固位种植体牙冠的患者进行复查。记录患者满意度、咬合和种植体周围参数、机械和生物学并发症、放射学参数以及美观情况。
对41例患者的前牙区和前磨牙区的总共50颗种植体牙冠进行了检查。最终修复体的随访期为1.1至3.8年。未发生技术和生物学并发症。复查时,100%的种植体和修复体均在位。放射学评估显示,随访检查时种植体肩部至首次可见的骨与种植体接触的平均距离为0.06mm。
基于带有十字扣连接的贴面CAD/CAM二氧化锆基台的螺丝固位牙冠似乎是在前牙区和前磨牙区替换缺失牙的一种有前景的方法。短期内,未观察到部件故障或并发症,临床和放射学数据显示软硬组织状况稳定。