Suppr超能文献

BioPlex 2200 HIV Ag-Ab 检测在识别急性 HIV 感染中的性能。

Performance of the BioPlex 2200 HIV Ag-Ab assay for identifying acute HIV infection.

机构信息

Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD, United States.

Statistical Center for AIDS Research and Prevention, Fred Hutchinson Cancer Research Center, Seattle, WA, United States.

出版信息

J Clin Virol. 2018 Feb-Mar;99-100:67-70. doi: 10.1016/j.jcv.2018.01.003. Epub 2018 Jan 11.

Abstract

BACKGROUND

Assays that detect HIV antigen (Ag) and antibody (Ab) can be used to screen for HIV infection.

OBJECTIVES

To compare the performance of the BioPlex 2200 HIV Ag-Ab assay and two other Ag/Ab combination assays for detection of acute HIV infection.

STUDY DESIGN

Samples were obtained from 24 individuals (18 from the US, 6 from South Africa); these individuals were classified as having acute infection based on the following criteria: positive qualitative RNA assay; two negative rapid tests; negative discriminatory test. The samples were tested with the BioPlex assay, the ARCHITECT HIV Ag/Ab Combo test, the Bio-Rad GS HIV Combo Ag-Ab EIA test, and a viral load assay.

RESULTS

Twelve (50.0%) of 24 samples had RNA detected only ( > 40 to 13,476 copies/mL). Ten (43.5%) samples had reactive results with all three Ag/Ab assays, one sample was reactive with the ARCHITECT and Bio-Rad assays, and one sample was reactive with the Bio-Rad and BioPlex assays. The 11 samples that were reactive with the BioPlex assay had viral loads from 83,010 to >750,000 copies/mL; 9/11 samples were classified as Ag positive/Ab negative by the BioPlex assay.

CONCLUSIONS

Detection of acute HIV infection was similar for the BioPlex assay and two other Ag/Ab assays. All three tests were less sensitive than a qualitative RNA assay and only detected HIV Ag when the viral load was high. The BioPlex assay detected acute infection in about half of the cases, and identified most of those infections as Ag positive/Ab negative.

摘要

背景

检测 HIV 抗原(Ag)和抗体(Ab)的检测可以用于筛查 HIV 感染。

目的

比较 BioPlex 2200 HIV Ag-Ab 检测与另外两种 Ag/Ab 组合检测在诊断急性 HIV 感染中的性能。

研究设计

从 24 名个体(18 名来自美国,6 名来自南非)中获得样本;这些个体根据以下标准被分类为急性感染:定性 RNA 检测阳性;两种快速检测阴性;鉴别检测阴性。用 BioPlex 检测、ARCHITECT HIV Ag/Ab Combo 检测、Bio-Rad GS HIV Combo Ag-Ab EIA 检测和病毒载量检测对样本进行检测。

结果

24 个样本中有 12 个(50.0%)仅检测到 RNA( > 40 至 13,476 拷贝/ml)。10 个(43.5%)样本与三种 Ag/Ab 检测均有反应性,1 个样本与 ARCHITECT 和 Bio-Rad 检测有反应性,1 个样本与 Bio-Rad 和 BioPlex 检测有反应性。与 BioPlex 检测有反应性的 11 个样本的病毒载量为 83,010 至>750,000 拷贝/ml;11 个样本中的 9 个被 BioPlex 检测分类为 Ag 阳性/Ab 阴性。

结论

BioPlex 检测与另外两种 Ag/Ab 检测在诊断急性 HIV 感染方面相似。所有三种检测方法都不如定性 RNA 检测敏感,仅在病毒载量较高时检测到 HIV Ag。BioPlex 检测在大约一半的病例中检测到急性感染,并确定大多数感染为 Ag 阳性/Ab 阴性。

相似文献

引用本文的文献

本文引用的文献

7
Human Immunodeficiency Virus Diagnostic Testing: 30 Years of Evolution.人类免疫缺陷病毒诊断检测:30年的发展历程
Clin Vaccine Immunol. 2016 Apr 4;23(4):249-53. doi: 10.1128/CVI.00053-16. Print 2016 Apr.
9
How can we better identify early HIV infections?我们如何能更好地识别早期HIV感染?
Curr Opin HIV AIDS. 2015 Jan;10(1):61-8. doi: 10.1097/COH.0000000000000121.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验