• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Therapeutic observation of subcutaneous pedicle screw-rod system with modified placement for Tile B pelvic fractures].

作者信息

Wu Xiao-Tian, Chen Nong, Pan Fu-Gen, Liu Zuo-Qing, He Xiao-Jian

机构信息

Department of Orthopaedics, Qingpu Branch of Zhongshan Hospital, Fudan University, Shanghai 201700, China.

Department of Orthopaedics, Qingpu Branch of Zhongshan Hospital, Fudan University, Shanghai 201700, China;

出版信息

Zhongguo Gu Shang. 2017 Mar 25;30(3):208-212. doi: 10.3969/j.issn.1003-0034.2017.03.004.

DOI:10.3969/j.issn.1003-0034.2017.03.004
PMID:29349956
Abstract

OBJECTIVE

To investigate the feasibility and therapeutic effect of subcutaneous pedicle screw-rod system with modified placement in treatment of Tile B pelvic fractures.

METHODS

From June 2014 to August 2015, 14 patients with Tile B pelvic fractures were treated by subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle. There were 8 males and 6 females, aged from 23 to 65 years with an average of 42 years. Operative time, intraoperative blood loss, fracture healing and postoperative complication were observed and clinical effects were evaluated by Matta reduction standard and Majeed score.

RESULTS

All patients were followed up from 8 to 15 months with an average of 10.5 months. Operative time was 25 to 45 min with an average of 32 min;intraoperative blood loss was 10 to 35 ml with an average of 18 ml. All fractures got primary healing and healed time was 9 to 14 weeks with an average of 12.5 weeks. No postoperative incision infection, internal fixation failure and ectopic ossification were found, 4 cases occurred unilateral lateral femoral cutaneous nerve injury and 1 case occurred unilateral femoral nerve paralysis, but all restored finally. According to Matta criteria, reduction was excellent in 7 cases, good in 5 cases, fair in 2 case. According to Majeed score system, the functional evaluation at last follow-up was excellent in 5 cases, good in 7 cases, fair in 2 cases with the average score of 81.50±8.05.

CONCLUSIONS

Subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle have advantages of strong reduction, less trauma and complications, and is a promising surgical method in the treatment of Tile B pelvic fractures.

摘要

相似文献

1
[Therapeutic observation of subcutaneous pedicle screw-rod system with modified placement for Tile B pelvic fractures].
Zhongguo Gu Shang. 2017 Mar 25;30(3):208-212. doi: 10.3969/j.issn.1003-0034.2017.03.004.
2
[Clinical application of percutaneous iliosacral screws combined with pubic ramus screws in Tile B pelvic fracture].经皮骶髂螺钉联合耻骨支螺钉在Tile B型骨盆骨折中的临床应用
Zhongguo Gu Shang. 2017 Mar 25;30(3):202-207. doi: 10.3969/j.issn.1003-0034.2017.03.003.
3
[Treatment of Day type pelvic crescent fracture by using percutaneous cannulated screw fixation technique].经皮空心螺钉固定技术治疗日型骨盆新月形骨折
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018 Feb 15;32(2):139-144. doi: 10.7507/1002-1892.2201709002.
4
[Anterior subcutaneous internal fixation combined with posterior percutaneous iliosacral screw for treatment of unstable pelvic fractures].前路皮下内固定联合后路经皮髂骶螺钉治疗不稳定骨盆骨折
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2020 Jan 15;34(1):21-26. doi: 10.7507/1002-1892.201905098.
5
Modified pedicle screw-rod fixation as a minimally invasive treatment for anterior pelvic ring injuries: an initial case series.改良椎弓根螺钉-棒固定术作为骨盆前环损伤的微创治疗:初步病例系列研究
J Orthop Surg Res. 2017 Jun 6;12(1):84. doi: 10.1186/s13018-017-0590-3.
6
Minimally invasive internal fixator for unstable pelvic ring injuries with a pedicle screw-rod system: a retrospective study of 23 patients after 13.5 months.带椎弓根螺钉棒系统的微创内固定器治疗不稳定骨盆环损伤:23例患者13.5个月后的回顾性研究
Arch Orthop Trauma Surg. 2019 Apr;139(4):489-496. doi: 10.1007/s00402-018-3094-7. Epub 2018 Dec 8.
7
Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod.使用连接至横向杆的椎弓根螺钉对骨盆后环不稳定进行微创稳定固定。
Int Orthop. 2018 Mar;42(3):681-686. doi: 10.1007/s00264-017-3714-9. Epub 2017 Dec 14.
8
Clinical and radiological short-term outcomes of pubic symphysis diastasis treated with modified pedicle screw-rod fixation.改良型椎弓根钉棒固定治疗耻骨联合分离的临床和影像学短期疗效。
Eur J Trauma Emerg Surg. 2020 Aug;46(4):865-871. doi: 10.1007/s00068-018-1050-4. Epub 2018 Nov 15.
9
[Treatment of unstable pelvic fractures by cannulated screw internal fixation with the assistance of three-dimensional printing insertion template].三维打印置入模板辅助空心螺钉内固定治疗不稳定骨盆骨折
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018 Feb 15;32(2):145-151. doi: 10.7507/1002-1892.201708059.
10
Minimally invasive treatment of unstable pelvic ring injuries with modified pedicle screw-rod fixator.改良椎弓根螺钉-棒固定器微创治疗不稳定骨盆环损伤
J Int Med Res. 2018 Jan;46(1):368-380. doi: 10.1177/0300060517715529. Epub 2017 Jun 29.