Suppr超能文献

一种用于增强动脉搭桥静脉移植物磁共振成像的可植入造影剂的早期动物模型评估。

Early animal model evaluation of an implantable contrast agent to enhance magnetic resonance imaging of arterial bypass vein grafts.

作者信息

Mitsouras Dimitrios, Tao Ming, de Vries Margreet R, Trocha Kaspar, Miranda Oscar R, Vemula Praveen Kumar, Ding Kui, Imanzadeh Amir, Schoen Frederick J, Karp Jeffrey M, Ozaki C Keith, Rybicki Frank J

机构信息

1 Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women's Hospital, Boston, MA, USA.

2 Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, ON, Canada.

出版信息

Acta Radiol. 2018 Sep;59(9):1074-1081. doi: 10.1177/0284185117753656. Epub 2018 Jan 29.

Abstract

Background Non-invasive monitoring of autologous vein graft (VG) bypass grafts is largely limited to detecting late luminal narrowing. Although magnetic resonance imaging (MRI) delineates vein graft intima, media, and adventitia, which may detect early failure, the scan time required to achieve sufficient resolution is at present impractical. Purpose To study VG visualization enhancement in vivo and delineate whether a covalently attached MRI contrast agent would enable quicker longitudinal imaging of the VG wall. Material and Methods Sixteen 12-week-old male C57BL/6J mice underwent carotid interposition vein grafting. The inferior vena cava of nine donor mice was treated with a gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA)-based contrast agent, with control VGs labeled with a vehicle. T1-weighted (T1W) MRI was performed serially at postoperative weeks 1, 4, 12, and 20. A portion of animals was sacrificed for histopathology following each imaging time point. Results MRI signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significantly higher for treated VGs in the first three time points (1.73 × higher SNR, P = 0.0006, and 5.83 × higher CNR at the first time point, P = 0.0006). However, MRI signal enhancement decreased consistently in the study period, to 1.29 × higher SNR and 2.64 × higher CNR, by the final time point. There were no apparent differences in graft morphometric analyses in Masson's trichrome-stained sections. Conclusion A MRI contrast agent that binds covalently to the VG wall provides significant increase in T1W MRI signal with no observed adverse effects in a mouse model. Further optimization of the contrast agent to enhance its durability is required.

摘要

背景

自体静脉移植物(VG)旁路移植的非侵入性监测在很大程度上局限于检测晚期管腔狭窄。尽管磁共振成像(MRI)能够描绘静脉移植物的内膜、中膜和外膜,这可能检测早期失败情况,但目前要获得足够分辨率所需的扫描时间并不实用。目的:研究体内静脉移植物(VG)可视化增强情况,并确定共价连接的MRI造影剂是否能实现对VG壁更快的纵向成像。材料与方法:16只12周龄雄性C57BL/6J小鼠接受颈动脉间置静脉移植。9只供体小鼠的下腔静脉用基于钆-二乙烯三胺五乙酸(Gd-DTPA)的造影剂处理,对照静脉移植物用赋形剂标记。在术后第1、4、12和20周连续进行T1加权(T1W)MRI检查。在每个成像时间点后,处死一部分动物进行组织病理学检查。结果:在前三个时间点,处理后的静脉移植物的MRI信噪比(SNR)和对比噪声比(CNR)显著更高(第一个时间点SNR高1.73倍,P = 0.0006,CNR高5.83倍,P = 0.0006)。然而,在研究期间MRI信号增强持续下降,到最后一个时间点时,SNR高1.29倍,CNR高2.64倍。在Masson三色染色切片中,移植物形态计量分析没有明显差异。结论:一种与静脉移植物壁共价结合的MRI造影剂在小鼠模型中可使T1W MRI信号显著增加,且未观察到不良反应。需要进一步优化造影剂以提高其耐久性。

相似文献

1
2
Mouse model of venous bypass graft arteriosclerosis.
Am J Pathol. 1998 Oct;153(4):1301-10. doi: 10.1016/S0002-9440(10)65675-1.
4
Comparison of ferumoxytol- and gadolinium chelate-enhanced MRI for assessment of sarcomas in children and adolescents.
Eur Radiol. 2020 Mar;30(3):1790-1803. doi: 10.1007/s00330-019-06569-y. Epub 2019 Dec 16.
5
Pre-clinical evaluation of a nanoparticle-based blood-pool contrast agent for MR imaging of the placenta.
Placenta. 2017 Sep;57:60-70. doi: 10.1016/j.placenta.2017.06.008. Epub 2017 Jun 15.
8
Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study.
Contrast Media Mol Imaging. 2013 Jan-Feb;8(1):63-71. doi: 10.1002/cmmi.1496.

本文引用的文献

1
Patient-Specific, Multi-Scale Modeling of Neointimal Hyperplasia in Vein Grafts.
Front Physiol. 2017 Apr 18;8:226. doi: 10.3389/fphys.2017.00226. eCollection 2017.
3
Mouse vein graft hemodynamic manipulations to enhance experimental utility.
Am J Pathol. 2011 Jun;178(6):2910-9. doi: 10.1016/j.ajpath.2011.02.014.
6
Rationale and practical techniques for mouse models of early vein graft adaptations.
J Vasc Surg. 2010 Aug;52(2):444-52. doi: 10.1016/j.jvs.2010.03.048. Epub 2010 Jun 22.
7
Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.
Int J Cardiovasc Imaging. 2010 Aug;26(6):683-91. doi: 10.1007/s10554-010-9621-4. Epub 2010 Mar 24.
9
Beyond the adventitia: exploring the outer limits of the blood vessel wall.
Circ Res. 2009 Feb 27;104(4):416-8. doi: 10.1161/CIRCRESAHA.109.194225.
10
Proinflammatory phenotype of perivascular adipocytes: influence of high-fat feeding.
Circ Res. 2009 Feb 27;104(4):541-9. doi: 10.1161/CIRCRESAHA.108.182998. Epub 2009 Jan 2.