Kanerva L, Jolanki R, Estlander T
Contact Dermatitis. 1986 Feb;14(2):80-4. doi: 10.1111/j.1600-0536.1986.tb01165.x.
A dental assistant developed sensitivity to dental restorative materials within 3 months of starting to use them. They contained the epoxy acrylate BIS-GMA, which is the most commonly used dimethacrylate monomer in dental composite restorations. She was positive to a patch test with BIS-GMA, which was the probable allergen, and epoxy resin, but this substance was not present in the materials used, as shown by high performance liquid chromatography. The patient was also allergic to the disinfectant Desimex i containing dodecyl diaminoethyl glycine.
一名牙科助理在开始使用牙科修复材料后的3个月内出现了对这些材料的过敏反应。这些材料含有环氧丙烯酸酯BIS - GMA,它是牙科复合修复材料中最常用的二甲基丙烯酸酯单体。她对BIS - GMA(可能的过敏原)和环氧树脂的斑贴试验呈阳性,但高效液相色谱分析表明,所用材料中不存在这种物质。该患者还对含有十二烷基二氨基乙基甘氨酸的消毒剂Desimex i过敏。