Suppr超能文献

4D 血流成像对保留瓣膜主动脉根部置换术(有无新窦)后主动脉血流生理学的新见解。

Novel insights by 4D Flow imaging on aortic flow physiology after valve-sparing root replacement with or without neosinuses.

作者信息

Galea Nicola, Piatti Filippo, Sturla Francesco, Weinsaft Jonathan W, Lau Christopher, Chirichilli Ilaria, Carbone Iacopo, Votta Emiliano, Catalano Carlo, De Paulis Ruggero, Girardi Leonard N, Redaelli Alberto, Gaudino Mario

机构信息

Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy.

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.

出版信息

Interact Cardiovasc Thorac Surg. 2018 Jun 1;26(6):957-964. doi: 10.1093/icvts/ivx431.

Abstract

OBJECTIVES

This study was undertaken to evaluate the flow dynamics in the aortic root after valve-sparing root replacement with and without neosinuses of Valsalva reconstruction, by exploiting the capability of 4D Flow imaging to measure in vivo blood velocity fields and 3D geometric flow patterns.

METHODS

Ten patients who underwent valve-sparing root replacement utilizing grafts with neosinuses or straight tube grafts (5 cases each) were evaluated by 4D Flow imaging at a mean of 46.5 months after surgery. We used in-house processing tools to quantify relevant bulk flow variables (flow rate, stroke volume, peak velocity and mean velocity), wall shear stresses and the amount of flow rotation characterizing the region enclosed by the graft and the aortic valve leaflets.

RESULTS

Despite bulk flows with similar peak velocities, flow rates and stroke volumes (P = 0.31-1.00), the neosinuses graft was associated with a lower mean velocity (P < 0.03) and magnitude of wall shear stress along the axial direction of the vessel wall (P < 0.05) at the proximal root level but remained comparable along the circumferential direction (P = 0.22-1.0) to the straight tube graft. Flow rotation was evidently and systematically higher in the neosinuses grafts, characterized by streamline rotations higher than 270°, nearly triple that of tubular grafts (10.3 ÷ 14.0% of all aortic streamline vs 2.2 ÷ 5.7%, P = 0.008).

CONCLUSIONS

Recreation of the sinuses of Valsalva during valve-sparing root replacement is associated with significantly lower wall shear stress and organized vortical flows at the level of the sinus that are not evident using the straight tube graft. These findings need confirmation in larger studies and could have important implications in terms of aortic valve durability.

摘要

目的

本研究旨在利用四维血流成像测量体内血流速度场和三维几何流动模式的能力,评估保留瓣膜的主动脉根部置换术在有或没有重建瓦尔萨尔瓦窦(新窦)的情况下主动脉根部的血流动力学。

方法

对10例行保留瓣膜主动脉根部置换术的患者进行评估,其中5例使用带新窦的移植物,5例使用直管移植物。术后平均46.5个月时采用四维血流成像进行评估。我们使用内部处理工具来量化相关的总体血流变量(流速、每搏量、峰值速度和平均速度)、壁面剪应力以及表征移植物和主动脉瓣叶所包围区域的血流旋转量。

结果

尽管峰值速度、流速和每搏量相似(P = 0.31 - 1.00), 但新窦移植物在根部近端水平的平均速度较低(P < 0.03),沿血管壁轴向的壁面剪应力大小也较低(P < 0.05),但在圆周方向上与直管移植物相当(P = 0.22 - 1.0)。新窦移植物中的血流旋转明显且系统地更高,其流线旋转高于270°,几乎是管状移植物的三倍(占所有主动脉流线的10.3%÷14.0%,而管状移植物为2.2%÷5.7%,P = 0.008)。

结论

保留瓣膜的主动脉根部置换术中重建瓦尔萨尔瓦窦与显著降低壁面剪应力以及窦水平有组织的涡流有关,而直管移植物则不明显出现这种情况。这些发现需要在更大规模的研究中得到证实,并且可能对主动脉瓣的耐久性具有重要意义。