Manzi Luigi, Villafañe Jorge Hugo, Indino Cristian, Tamini Jacopo, Berjano Pedro, Usuelli Federico Giuseppe
IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
IRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Foot Ankle Surg. 2019 Apr;25(2):169-173. doi: 10.1016/j.fas.2017.10.009. Epub 2017 Nov 8.
The purpose of this study was to investigate the test-retest reliability of the Phi angle in patients undergoing total ankle replacement (TAR) for end stage ankle osteoarthritis (OA) to assess the rotational alignment of the talar component.
Retrospective observational cross-sectional study of prospectively collected data. Post-operative anteroposterior radiographs of the foot of 170 patients who underwent TAR for the ankle OA were evaluated. Three physicians measured Phi on the 170 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), inter and intra-observer agreement were evaluated.
Test-retest reliability of Phi angle measurement was excellent for patients with Hintegra TAR (ICC=0.995; p<0.001) and Zimmer TAR (ICC=0.995; p<0.001) on radiographs of subjects with ankle OA. There were no significant differences in the reliability of the Phi angle measurement between patients with Hintegra vs. Zimmer implants (p>0.05).
Measurement of Phi angle on weight-bearing dorsoplantar radiograph showed an excellent reliability among orthopaedic surgeons in determining the position of the talar component in the axial plane.
Level II, cross sectional study.
本研究的目的是调查终末期踝骨关节炎(OA)患者行全踝关节置换术(TAR)时Phi角的重测信度,以评估距骨组件的旋转对线情况。
对前瞻性收集的数据进行回顾性观察性横断面研究。评估了170例因踝OA行TAR患者术后足部的前后位X线片。三名医生在相隔一周的两个时间点(测试和重测条件),对170张随机排序且匿名的X线片测量Phi角,评估观察者间和观察者内的一致性。
在踝OA患者的X线片上,对于使用Hintegra TAR(组内相关系数[ICC]=0.995;p<0.001)和Zimmer TAR(ICC=0.995;p<0.001)的患者,Phi角测量的重测信度极佳。使用Hintegra与Zimmer植入物的患者之间,Phi角测量的信度无显著差异(p>0.05)。
负重背跖位X线片上Phi角的测量在骨科医生确定距骨组件在轴平面的位置时显示出极佳的信度。
II级横断面研究。