Suppr超能文献

使用基于硼酸的琼脂糖珠在纸基装置上测定糖化白蛋白。

Determination of glycated albumin using boronic acid-derived agarose beads on paper-based devices.

作者信息

Ko Euna, Tran Van-Khue, Geng Yanfang, Kim Min Ki, Jin Ga Hyun, Son Seong Eun, Hur Won, Seong Gi Hun

机构信息

Department of Bionano Engineering, Hanyang University, Ansan 426-791, South Korea.

出版信息

Biomicrofluidics. 2018 Feb 1;12(1):014111. doi: 10.1063/1.5021395. eCollection 2018 Jan.

Abstract

Self-monitoring of glycated albumin (GA), a useful glycemic marker, is an established method for preventing diabetes complications. Here, the paper-based lateral flow assay devices were developed for the sensitive detection of GA and the total human serum albumin (tHSA) in self-monitoring diabetes patients. Boronic acid-derived agarose beads were packed into a hole on a lateral flow channel. These well-coordinated agarose beads were used to capture GA through specific cis-diol interactions and to enhance the colorimetric signals by concentrating the target molecules. The devices exhibited large dynamic ranges (from 10 g/ml to 10 mg/ml for GA and from 10 mg/ml to 50 mg/ml for tHSA) and low detection limits (7.1 g/ml for GA and 4.7 mg/ml for tHSA), which cover the range of GA concentration in healthy plasma, which is 0.21-1.65 mg/ml (0.6%-3%). In determining the unknown GA concentrations in two commercial human plasma samples, the relative percentage difference between the values found by a standard ELISA kit and those found by our developed devices was 2.62% and 8.80%, which are within an acceptable range. The measurements of GA and tHSA were completed within 20 min for the total sample-to-answer diagnosis, fulfilling the demand for rapid analysis. Furthermore, the recovery values ranged from 99.4% to 110% in device accuracy tests. These results indicate that the developed paper-based device with boronic acid-derived agarose beads is a promising platform for GA and tHSA detection as applied to self-monitoring systems.

摘要

糖化白蛋白(GA)的自我监测是一种有用的血糖标志物,是预防糖尿病并发症的既定方法。在此,开发了基于纸的侧向流动分析装置,用于在糖尿病患者自我监测中灵敏检测GA和总人血清白蛋白(tHSA)。将硼酸衍生的琼脂糖珠填充到侧向流动通道上的一个孔中。这些协调良好的琼脂糖珠用于通过特定的顺式二醇相互作用捕获GA,并通过浓缩目标分子增强比色信号。该装置具有较大的动态范围(GA为10μg/ml至10mg/ml,tHSA为10mg/ml至50mg/ml)和低检测限(GA为7.1μg/ml,tHSA为4.7mg/ml),涵盖了健康血浆中GA浓度范围,即0.21 - 1.65mg/ml(0.6% - 3%)。在测定两个商业人血浆样品中的未知GA浓度时,标准ELISA试剂盒测得的值与我们开发的装置测得的值之间的相对百分比差异分别为2.62%和8.80%,在可接受范围内。对于整个样品到结果的诊断,GA和tHSA的测量在20分钟内完成,满足了快速分析的需求。此外,在装置准确性测试中,回收率值在99.4%至110%之间。这些结果表明,所开发的带有硼酸衍生琼脂糖珠的基于纸的装置是应用于自我监测系统的GA和tHSA检测的有前景的平台。

相似文献

本文引用的文献

2
Hydrogel-driven paper-based microfluidics.水凝胶驱动的纸基微流控技术。
Lab Chip. 2015 Jun 7;15(11):2452-9. doi: 10.1039/c5lc00276a. Epub 2015 Apr 27.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验