Ding Xuefang, Suzuki Shoichi, Shiga Momotoshi, Ohbayashi Naoto, Kurabayashi Toru, Moriyama Keiji
Department of Stomatology, Beijing Jishuitan Hospital, Beijing, China.
Maxillofacial Orthognathics, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan.
Odontology. 2018 Jul;106(3):266-273. doi: 10.1007/s10266-017-0335-0. Epub 2018 Feb 21.
The aims of this study were to reveal the usefulness of a newly developed method for measuring tongue volume (TV) and oral cavity capacity (OCC) and to assess the relationship between them. The tongue was coated with a contrast agent, and the TV and OCC were determined using cone-beam computed tomography (CBCT). We enrolled 20 adults who were scheduled to undergo CBCT to evaluate the relationship of the third molar roots to the alveolar nerve before molar extraction. Each participant's tongue was coated with a contrast agent, and CBCT of the tongue and oral cavity was performed. Using computer software, we evaluated reconstructed 3D images of the TV, oral cavity proper volume (OCPV), and OCC. The mean TV was 47.07 ± 7.08 cm. The mean OCPV and OCC were 4.40 ± 2.78 cm and 51.47 ± 6.46 cm, respectively. There was a significant correlation between TV and OCC (r = 0.920; p < 0.01) but not between TV and OCPV. The mean TV/OCC ratio was 91 ± 5%. The proposed method produced CBCT images that enabled effective measurement of TV and OCC. This simple method of measuring TV and OCC will be useful in the diagnosis on the tongues with abnormal size.
本研究的目的是揭示一种新开发的测量舌体积(TV)和口腔容量(OCC)的方法的实用性,并评估它们之间的关系。在舌部涂抹造影剂,然后使用锥形束计算机断层扫描(CBCT)测定TV和OCC。我们招募了20名计划接受CBCT以评估第三磨牙牙根与磨牙拔除术前牙槽神经关系的成年人。给每位参与者的舌部涂抹造影剂,然后对舌部和口腔进行CBCT扫描。使用计算机软件,我们评估了TV、口腔固有容积(OCPV)和OCC的重建三维图像。平均TV为47.07±7.08cm。平均OCPV和OCC分别为4.40±2.78cm和51.47±6.46cm。TV与OCC之间存在显著相关性(r = 0.920;p < 0.01),但TV与OCPV之间无显著相关性。平均TV/OCC比值为91±5%。所提出的方法生成的CBCT图像能够有效测量TV和OCC。这种测量TV和OCC的简单方法将有助于诊断尺寸异常的舌部。