Suppr超能文献

调制检测干扰在人工耳蜗植入者在正向掩蔽条件下。

Modulation detection interference in cochlear implant listeners under forward masking conditions.

机构信息

Auditory Prostheses and Perception Laboratory, Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68104, USA.

出版信息

J Acoust Soc Am. 2018 Feb;143(2):1117. doi: 10.1121/1.5025059.

Abstract

Little is known about cochlear implant (CI) users' ability to process amplitude modulation (AM) under conditions of forward masking (forward-modulation detection/discrimination interference, or F-MDI). In this study, F-MDI was investigated in adult CI listeners using direct electrical stimulation via research interface. The target was sinusoidally amplitude modulated at 50 Hz, and presented to a fixed electrode in the middle of the array. The forward masker was either amplitude modulated at the same rate (AM) or unmodulated and presented at the peak amplitude of its AM counterpart (steady-state peak, SSP). Results showed that the AM masker produced higher modulation thresholds in the target than the SSP masker. The difference (F-MDI) was estimated to be 4.6 dB on average, and did not change with masker-target delays up to 100 ms or with masker-target spatial electrode distances up to eight electrodes. Results with a coherent remote cue presented with the masker showed that confusion effects did not play a role in the observed F-MDI. Traditional recovery from forward masking using the same maskers and a 20-ms probe, measured in four of the subjects, confirmed the expected result: higher thresholds with the SSP masker than the AM masker. Collectively, the results indicate that significant F-MDI occurs in CI users.

摘要

关于人工耳蜗植入(CI)用户在正向掩蔽(前调制检测/辨别干扰,或 F-MDI)条件下处理幅度调制(AM)的能力知之甚少。在这项研究中,使用研究接口通过直接电刺激研究了成年 CI 聆听者的 F-MDI。目标是在 50Hz 下正弦幅度调制,在阵列中间的固定电极呈现。前掩蔽器要么以相同的速率(AM)进行调制,要么不调制并在其 AM 对应物的峰值幅度处呈现(稳态峰值,SSP)。结果表明,AM 掩蔽器在目标上产生的调制阈值比 SSP 掩蔽器高。差异(F-MDI)平均估计为 4.6dB,并且不随掩蔽器-目标延迟高达 100ms 或掩蔽器-目标空间电极距离高达 8 个电极而改变。与掩蔽器一起呈现的相干远程提示的结果表明,混淆效应在观察到的 F-MDI 中不起作用。使用相同的掩蔽器和 20ms 探针在四个受试者中测量的传统前向掩蔽恢复证实了预期的结果:SSP 掩蔽器的阈值高于 AM 掩蔽器。总的来说,结果表明 CI 用户中存在显著的 F-MDI。

相似文献

本文引用的文献

7
Forward masking of amplitude modulation: basic characteristics.调幅的前向掩蔽:基本特征
J Acoust Soc Am. 2005 Nov;118(5):3198-210. doi: 10.1121/1.2042970.
9
Modulation masking in cochlear implant listeners: envelope versus tonotopic components.
J Acoust Soc Am. 2003 Apr;113(4 Pt 1):2042-53. doi: 10.1121/1.1555613.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验