Suppr超能文献

基于丙烯酸盐整体聚合物、液相色谱分析和实验设计方法的搅拌棒吸附萃取法对人血浆中氯沙坦和缬沙坦的验证测定。

Validated determination of losartan and valsartan in human plasma by stir bar sorptive extraction based on acrylate monolithic polymer, liquid chromatographic analysis and experimental design methodology.

机构信息

Department of Chemistry, Faculty of Physics & Chemistry, Alzahra University, Tehran, Iran.

Department of Chemistry, Faculty of Physics & Chemistry, Alzahra University, Tehran, Iran.

出版信息

J Pharm Biomed Anal. 2018 May 10;153:204-213. doi: 10.1016/j.jpba.2018.02.030. Epub 2018 Feb 21.

Abstract

In our previous work, a new monolithic coating based on vinylpyrrolidone-ethylene glycol dimethacrylate polymer was introduced for stir bar sorptive extraction. The formulation of the prepared vinylpyrrolidone-ethylene glycol dimethacrylate monolithic polymer was optimized and the satisfactory quality of prepared coated stir bar was demonstrated. In this work, the prepared stir bar was utilized in combination with ultrasound-assisted liquid desorption, followed by high-performance liquid chromatography with ultraviolet detection for the simultaneous determination of losartan (LOS) and valsartan (VAS) in human plasma samples. In a comparison study, the extraction efficiency of the prepared stir bar was accompanied much higher extraction efficiency than the two commercial stir bars (polydimethylsiloxand and polyacrylate) for both target compounds. In order to improve the desorption efficiency of LOS and VAS, the best values for effective parameters on desorption step were selected systematically. Also, the effective parameters on extraction step were optimized using a Box-Behnken design. Under the optimum conditions, the analytical performance of the proposed method displayed excellent linear dynamic ranges for LOS (24-1000 ng mL) and VAS (91-1000 ng mL), with correlation coefficients of 0.9998 and 0.9971 and detection limits of 7 and 27 ng mL, respectively. The intra- and inter-day recovery ranged from 98 to 117%, and the relative standard deviations were less than 8%. Finally, the proposed technique was successfully applied to the analysis of LOS and VAS at their therapeutic levels in volunteer patient plasma sample. The obtained results were confirmed using liquid chromatography-mass spectrometry. The proposed technique was more rapid than previously reported stir bar sorptive extraction techniques based on monolithic coatings, and exhibited lower detection limits in comparison with similar methods for the determination of LOS and VLS in biological fluids. The obtained results were demonstrated that the lower selectivity of UV in comparison with MS detection was rectified by appropriate sample preparation through proposed extraction method to eliminate as many interfering compounds as possible.

摘要

在我们之前的工作中,引入了一种基于乙烯基吡咯烷酮-乙二醇二甲基丙烯酸酯聚合物的新型整体涂层,用于搅拌棒吸附萃取。优化了制备的乙烯基吡咯烷酮-乙二醇二甲基丙烯酸酯整体聚合物的配方,并证明了制备的涂层搅拌棒具有令人满意的质量。在这项工作中,利用制备的搅拌棒结合超声辅助液解吸,然后采用高效液相色谱法结合紫外检测,同时测定人血浆样品中的氯沙坦(LOS)和缬沙坦(VAS)。在对比研究中,与两种商业搅拌棒(聚二甲基硅氧烷和聚丙烯酸酯)相比,制备的搅拌棒对两种目标化合物的萃取效率更高。为了提高 LOS 和 VAS 的解吸效率,系统地选择了最佳的解吸步骤有效参数值。此外,还使用 Box-Behnken 设计优化了萃取步骤的有效参数。在最佳条件下,所提出方法的分析性能对 LOS(24-1000ng/mL)和 VAS(91-1000ng/mL)表现出极好的线性动态范围,相关系数分别为 0.9998 和 0.9971,检测限分别为 7 和 27ng/mL。日内和日间回收率在 98%至 117%之间,相对标准偏差小于 8%。最后,该技术成功应用于志愿者患者血浆样品中治疗水平下的 LOS 和 VAS 分析。使用液相色谱-质谱法对获得的结果进行了验证。与以前报道的基于整体涂层的搅拌棒吸附萃取技术相比,该技术更加快速,与用于生物体液中 LOS 和 VLS 测定的类似方法相比,检测限更低。所获得的结果表明,通过适当的样品制备,通过提出的萃取方法消除尽可能多的干扰化合物,可以纠正与 MS 检测相比,UV 检测的选择性较低的问题。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验