Suppr超能文献

超声图像评估青少年特发性脊柱侧凸非手术候选者脊柱柔韧性的测量的组内和组间信度:一项初步研究。

Intra- and inter-rater reliability of spinal flexibility measurements using ultrasonic (US) images for non-surgical candidates with adolescent idiopathic scoliosis: a pilot study.

机构信息

Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Canada.

Department of Surgery, University of Alberta, Edmonton, Canada.

出版信息

Eur Spine J. 2018 Sep;27(9):2156-2164. doi: 10.1007/s00586-018-5546-8. Epub 2018 Mar 9.

Abstract

PURPOSE

This study aimed to determine the intra- and inter-rater reliabilities of spinal flexibility measurements using ultrasound imaging on non-surgical candidates with adolescent idiopathic scoliosis (AIS).

METHODS

Twenty-eight consecutive consented AIS subjects (25 F; 3 M) were recruited; 24 subjects' data were used for analysis. This study explored curve magnitude differences between standing, prone and voluntary maximum side-bending postures to assess the reliability of spinal flexibility (SF). Two raters were included in this study. Four flexibility indices, PRSI, BRPI, B-PRSI, BRSI, based on the postural changes from standing to prone and from prone to bending position were defined. The reliability analysis was evaluated using the intra-class correlation coefficient (ICC) [1, 2] and the standard error of measurements (SEM).

RESULTS

The ICC [1, 2] values of the intra-rater (R2 only) and inter-rater (R1 vs R2) reliabilities of the measurements (PRSI, BRPI, B-PRSI, BRSI) were (0.82, 0.64, 0.78, 0.91) and (0.78, 0.76, 0.84, 0.94), respectively. Among the four indices, the BRPI had the highest SEM values 1.42, and 0.73 for intra- and inter-raters results, respectively, while BRSI had the lowest SEM 0.04 and 0.02 for intra- and inter-rater, respectively.

CONCLUSIONS

The BRPI, BRSI and B-PRSI could be measured reliably on US images when the Cobb angle at prone position was not close to zero. Using these three indices, information may provide more comprehensive information about the SF. Validity of spinal flexibility measurements still needed to be confirmed with a clinical study with more subjects. These slides can be retrieved under Electronic Supplementary Material.

摘要

目的

本研究旨在确定非手术候选的青少年特发性脊柱侧凸(AIS)患者使用超声成像进行脊柱柔韧性测量的组内和组间可信度。

方法

共招募了 28 名连续同意的 AIS 受试者(25 名女性;3 名男性);24 名受试者的数据用于分析。本研究通过站立、俯卧和自愿最大侧弯曲姿势之间的曲线幅度差异来评估脊柱柔韧性(SF)的可靠性。本研究包括 2 名评估者。根据从站立到俯卧和从俯卧到弯曲位置的姿势变化,定义了 4 个柔韧性指数,PRSI、BRPI、B-PRSI、BRSI。使用组内相关系数(ICC)[1,2]和测量标准误差(SEM)评估可靠性分析。

结果

(仅 R2)的组内(R2 仅)和组间(R1 与 R2)测量值(PRSI、BRPI、B-PRSI、BRSI)的可信度的 ICC [1,2]值分别为(0.82、0.64、0.78、0.91)和(0.78、0.76、0.84、0.94)。在这四个指数中,BRPI 的 SEM 值最高,组内和组间结果分别为 1.42 和 0.73,而 BRSI 的 SEM 值最低,组内和组间结果分别为 0.04 和 0.02。

结论

当俯卧位 Cobb 角接近零时,BRPI、BRSI 和 B-PRSI 可以在 US 图像上可靠测量。使用这三个指数,可以提供关于 SF 的更全面的信息。脊柱柔韧性测量的有效性仍需要通过更多受试者的临床研究来证实。这些幻灯片可以在电子补充材料中检索。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验