Suppr超能文献

在医院环境中,使用活动监测器对亚急性中风患者进行基于强度的身体活动测量的可靠性:一项横断面研究。

Reliability of intensity-based physical activity measurement using an activity monitor in people with subacute stroke in the hospital setting: a cross-sectional study.

作者信息

Shimizu Natsuki, Hashidate Hiroyuki, Ota Tomohiro, Saito Akihiko

机构信息

a Major in Health Sciences , The Graduate School of Kyorin University , Mitaka , Japan.

b Hatsudai Rehabilitation Hospital , Shibuya , Japan.

出版信息

Top Stroke Rehabil. 2018 May;25(4):288-294. doi: 10.1080/10749357.2018.1446486. Epub 2018 Mar 12.

Abstract

Background Activity monitors are known to provide quantitative evaluation of physical activity in people with stroke. However, little evidence is available on the test-retest reliability and suitable measuring conditions for evaluating physical activity with an activity monitor in people with subacute stroke at a hospital setting. Objectives To evaluate reliability of physical activity measurement using an activity monitor in different measuring conditions in hospitalized people with subacute stroke according to gait ability. Methods Sixty-nine participants with subacute stroke were categorized based on their gait ability: group 1 (n = 22), could walk independently at sufficient gait speed (≥0.9 m/s); group 2 (n = 11), could walk independently with insufficient gait speed (<0.9 m/s); group 3 (n = 36), required assistance in walking. Physical activity (sedentary behavior, light-intensity physical activity, moderate-to-vigorous physical activity) was measured using an activity monitor (OMRON, HJA350-IT) for seven consecutive days. All physical activity variables were calculated in five conditions defined according to measurement periods (3, 5, or 7 days with or without weekends). Results In groups 1 and 2, intraclass correlation coefficients were high across all measuring conditions in all physical activity variables (>0.7). In group 3, intraclass correlation coefficients were high in all measuring conditions (>0.7) except for three weekdays measuring condition (0.563-0.922). Conclusions In hospitalized people with subacute stroke, the central tendency of intensity-based physical activity could be assessed with good reliability using an activity monitor. For reliable measurement, more measurement days are needed in those with dependent walking compared to those with independent walking.

摘要

背景

活动监测器可用于对中风患者的身体活动进行定量评估。然而,在医院环境中,对于亚急性中风患者使用活动监测器评估身体活动的重测信度和合适测量条件,几乎没有相关证据。

目的

根据步态能力,评估在不同测量条件下,使用活动监测器对住院亚急性中风患者身体活动测量的可靠性。

方法

69名亚急性中风参与者根据其步态能力进行分类:第1组(n = 22),能够以足够的步态速度(≥0.9 m/s)独立行走;第2组(n = 11),能够独立行走,但步态速度不足(<0.9 m/s);第3组(n = 36),行走需要协助。使用活动监测器(欧姆龙,HJA350-IT)连续7天测量身体活动(久坐行为、轻度身体活动、中度至剧烈身体活动)。所有身体活动变量在根据测量周期定义的五种条件下计算(有或无周末的3、5或7天)。

结果

在第1组和第2组中,所有身体活动变量在所有测量条件下的组内相关系数均较高(>0.7)。在第3组中,除三个工作日测量条件外(0.563 - 0.922),所有测量条件下的组内相关系数均较高(>0.7)。

结论

在住院亚急性中风患者中,使用活动监测器可以可靠地评估基于强度的身体活动的集中趋势。为了获得可靠的测量结果,与独立行走的患者相比,依赖行走的患者需要更多的测量天数。