Department of Vascular and Endovascular Surgery, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Zhengzhou, PR China.
Department of Interventional Radiology, First Affiliated Hospital of China Medical University, Liaoning, PR China.
Eur J Vasc Endovasc Surg. 2018 Jun;55(6):842-850. doi: 10.1016/j.ejvs.2018.02.021. Epub 2018 Mar 23.
The aim was to evaluate the feasibility and safety of a new unibody branched stent graft for the reconstruction of the canine aortic arch.
The unibody branched stent grafts included single branched stent grafts and double branched stent grafts. The main stent graft and branched limbs were sutured together. The branched stent grafts were folded into the introducer system, which consisted of a double channel catheter, a detachable sleeve, and an introducer sheath. The branched stent grafts were introduced and deployed into the aortic arch by the delivery system. Twenty adult mongrel dogs were used for the experiments. Ten dogs were implanted with single branched stent grafts; the other 10 were implanted with double branched stent grafts. The surviving animals were followed up for 3 months. Computed tomography angiography (CTA) was performed to observe the status of the branched stent grafts.
All the unibody branched stent grafts were successfully implanted into the canine aortic arches. The technical success rate was 100%. There was no cerebral infarction, paraplegia or incision infection. CTA showed that all the branched stent grafts were patent; there was no endoleak or stent migration.
The unibody branched stent graft system could be used to reconstruct the aortic arch. The animal experimental procedures demonstrated the safety and feasibility of the unibody branched stent graft system.
评估一种新型一体式分支型覆膜支架治疗犬主动脉弓的可行性和安全性。
一体式分支型覆膜支架包括单分支型覆膜支架和双分支型覆膜支架。主覆膜支架和分支支架通过缝合连接在一起。分支覆膜支架折叠放入输送系统中,输送系统由双通道导管、可分离套管和输送鞘组成。通过输送系统将分支覆膜支架引入并部署到主动脉弓中。
实验使用 20 只成年杂种犬。其中 10 只犬植入单分支型覆膜支架,另 10 只犬植入双分支型覆膜支架。对存活的动物进行 3 个月的随访。通过计算机断层血管造影(CTA)观察分支覆膜支架的状态。
所有一体式分支型覆膜支架均成功植入犬主动脉弓,技术成功率为 100%。无脑梗死、截瘫或切口感染。CTA 显示所有分支覆膜支架均通畅,无内漏或支架移位。
一体式分支型覆膜支架系统可用于重建主动脉弓。动物实验程序证明了一体式分支型覆膜支架系统的安全性和可行性。