Suppr超能文献

冠状动脉成形术期间远端阻塞压力与血管造影显示的侧支血流之间关系的评估。

Assessment of the relationship between distal occluded pressure and angiographically evident collateral flow during coronary angioplasty.

作者信息

Dervan J P, McKay R G, Baim D S

出版信息

Am Heart J. 1987 Sep;114(3):491-7. doi: 10.1016/0002-8703(87)90743-5.

Abstract

The relationship between the presence of collateral filling on the baseline coronary angiogram and the distal occluded pressure obtained during balloon inflation was examined in 83 patients undergoing coronary angioplasty. The patients were divided into three groups: Group I (n = 40) had conventional stenoses (80% to 95% luminal diameter narrowing) without angiographically evident collaterals, group II (n = 22) had conventional stenoses with angiographically present collaterals, and group III (n = 21) had total or functional total occlusions (99% to 100% diameter narrowing) with angiographically evident collateral flow. There was no significant difference in age, sex, vessel distribution, clinical class, residual gradient, or residual percent stenosis following successful angioplasty among the three groups. The distal occluded pressure in group I (18 +/- 5 mm Hg) was, however, significantly lower than the distal occluded pressure in either group II (34 +/- 7 mm Hg) or group III (36 +/- 9 mm Hg) (p less than 0.001). This could not be explained by differences in aortic pressure, since there was no correlation between the mean aortic blood pressure and the distal occluded pressure and since the distal occluded pressure/aortic pressure ratio in group I (0.23 +/- 0.07) was significantly lower than that of group II (0.41 +/- 0.09) or group III (0.41 +/- 0.11) (p less than 0.001). These findings indicate a close correlation between the presence of angiographically evident collateral flow and the distal coronary artery pressure during an angioplasty balloon inflation.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

在83例行冠状动脉成形术的患者中,研究了基线冠状动脉血管造影时侧支循环充盈情况与球囊扩张时获得的远端闭塞压力之间的关系。患者被分为三组:第一组(n = 40)有传统狭窄(管腔直径狭窄80%至95%)且血管造影未显示明显侧支循环;第二组(n = 22)有传统狭窄且血管造影显示有侧支循环;第三组(n = 21)有完全或功能性完全闭塞(直径狭窄99%至100%)且血管造影显示有明显侧支血流。三组患者在年龄、性别、血管分布、临床分级、残余梯度或成功血管成形术后的残余狭窄百分比方面无显著差异。然而,第一组的远端闭塞压力(18±5 mmHg)显著低于第二组(34±7 mmHg)或第三组(36±9 mmHg)(p<0.001)。这无法用主动脉压力差异来解释,因为平均主动脉血压与远端闭塞压力之间无相关性,且第一组的远端闭塞压力/主动脉压力比值(0.23±0.07)显著低于第二组(0.41±0.09)或第三组(0.41±0.11)(p<0.001)。这些发现表明血管造影显示的明显侧支血流的存在与冠状动脉成形术球囊扩张期间的远端冠状动脉压力密切相关。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验