Suppr超能文献

比较手持式便携测力计与固定式等速测力计测量手腕和前臂力量的差异。

Comparison of portable handheld versus fixed isokinetic dynamometers in measuring strength of the wrist and forearm.

机构信息

a Department of Physical Therapy , Mercer University , Atlanta , GA , USA.

b Department of Physical Therapy , DeKalb Medical Center , Decatur , GA , USA.

出版信息

Physiother Theory Pract. 2019 Jul;35(7):677-685. doi: 10.1080/09593985.2018.1455248. Epub 2018 Mar 28.

Abstract

: The purpose of this study was to test the concurrent validity of using hydraulic dynamometers in comparison to the gold standard isokinetic dynamometers in measuring wrist and forearm strength. : Healthy adults between the ages of 18-65 participated, including 24 participants, 8 men and 16 women. The examiner used a handheld dynamometer, forearm/wrist dynamometer, and an isokinetic dynamometer to measure force/torque production in forearm rotation and wrist flexion/extension using a standardized protocol of two handle types for each motion. Sequence of testing was randomized. The data were analyzed using Pearson correlation coefficients and paired -tests. : When matched for handle type, three of the four correlations between the strength measurements taken with the different dynamometers were moderate to high with Pearson product moment coefficients ranging from 0.72 to 0.96; the screwdriver handle demonstrated less than acceptable correlation ( = 0.45, 0.67 for wrist flexion and extension, respectively). There were significant differences in most of the force/torque values obtained by different handle types for wrist and forearm motions. : Overall, the dynamometers demonstrated acceptable correlations supporting concurrent validity for measuring forearm and wrist strength, except with the screwdriver handle. However, different tools, positions, and handle interfaces provided different absolute values, therefore the tools cannot be used interchangeably. It is recommended that repeated measurements to monitor patient progress are taken with the same tool and handle type.

摘要

: 本研究旨在测试使用液压测力计与黄金标准等速测力计相比,在测量手腕和前臂力量方面的同时效度。 : 健康成年人年龄在 18-65 岁之间,共有 24 名参与者,包括 8 名男性和 16 名女性。检查者使用手持式测力计、前臂/手腕测力计和等速测力计,按照两种运动类型的标准方案,测量前臂旋转和手腕屈伸时的力量/扭矩产生。测试顺序是随机的。使用 Pearson 相关系数和配对检验对数据进行分析。 : 在匹配手柄类型时,不同测力计测量的力量之间有三种相关性在中度到高度之间,Pearson 乘积矩系数范围为 0.72 到 0.96;螺丝刀手柄的相关性较差(手腕屈伸的 Pearson 系数分别为 0.45 和 0.67)。对于手腕和前臂运动,不同手柄类型获得的大多数力/扭矩值存在显著差异。 : 总体而言,测力计在测量前臂和手腕力量方面具有可接受的相关性,支持同时效度,除了螺丝刀手柄。然而,不同的工具、位置和手柄接口提供了不同的绝对值,因此这些工具不能互换使用。建议使用相同的工具和手柄类型进行重复测量以监测患者进展。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验