Reduction of Donor Cornea Exposure to Repeat Warming Cycles and Evaluation Times After Implementation of a Rapid Warming Protocol.

作者信息

Clover Jameson, Ansin Amy, Stoeger Christopher G, Terry Mark A, Tran Khoa D

机构信息

Vision Research Laboratory, Lions VisionGift, Portland, OR.

Cornea Services, Devers Eye Institute, Portland, OR.

出版信息

Cornea. 2018 Jul;37(7):829-833. doi: 10.1097/ICO.0000000000001583.

Abstract

PURPOSE

To compare tissue evaluation times and specular image quality before and after the implementation of rapid tissue warming at a single eye bank.

METHODS

This retrospective study compares the evaluation of 494 donor corneas. All corneas were stored in Optisol-GS. Group 1 contained 247 corneas evaluated immediately before implementation of a tissue incubator and tissue warming protocol. Group 2 contained 247 corneas evaluated immediately after implementation. Total evaluation times (including specular microscopy, optical coherence tomography for corneal thickness measurements, and 2 slit-lamp examinations) were calculated and compared. Representative specular images of donor corneas were rated and compared using a previously described scale by 2 masked readers.

RESULTS

Donor tissue characteristics were not significantly different between both groups (age, P = 0.87; sex, P = 0.93; endothelial cell densities, P = 0.47; and death-to-preservation times, P = 0.18). The mean total evaluation time for group 2 corneas was ∼3 hours, with 97% (201/208) of evaluations completed on the same day. In contrast, only 73% (164/225) of corneas from group 1 were completely evaluated in 1 day, and the mean evaluation time for those corneas was ∼4.25 hours (P < 0.01). Specular images of corneas from group 2 were rated 1 grade higher, on average, than those from group 1 (n = 247 in each group, P < 0.01). Furthermore, 71% of specular images from group 2 were categorized as "good" or "excellent" quality, whereas only 30% of corneas from group 1 received those ratings.

CONCLUSIONS

Rapid tissue warming cuts down on tissue evaluation time and reduces the time donor corneas are out of cold storage. Better specular images were obtained after implementation of the rapid warming protocol.

摘要

目的

比较在单一眼库实施快速组织加温前后的组织评估时间和镜面反射图像质量。

方法

这项回顾性研究比较了494只供体角膜的评估情况。所有角膜均储存在Optisol-GS中。第1组包含247只在实施组织培养箱和组织加温方案之前立即评估的角膜。第2组包含247只在实施之后立即评估的角膜。计算并比较总评估时间(包括镜面反射显微镜检查、用于角膜厚度测量的光学相干断层扫描以及2次裂隙灯检查)。由2名盲法阅片者使用先前描述的量表对供体角膜的代表性镜面反射图像进行评分和比较。

结果

两组之间的供体组织特征无显著差异(年龄,P = 0.87;性别,P = 0.93;内皮细胞密度,P = 0.47;死亡至保存时间,P = 0.18)。第2组角膜的平均总评估时间约为3小时,97%(201/208)的评估在同一天完成。相比之下,第1组只有73%(164/225)的角膜在1天内完成了全面评估,这些角膜的平均评估时间约为4.25小时(P < 0.01)。第2组角膜的镜面反射图像平均评分比第1组高1级(每组n = 247,P < 0.01)。此外,第2组71%的镜面反射图像被归类为“良好”或“优秀”质量,而第1组只有30%的角膜获得这些评级。

结论

快速组织加温减少了组织评估时间,并缩短了供体角膜脱离冷藏的时间。实施快速加温方案后获得了更好的镜面反射图像。