Suppr超能文献

朝向用于治疗情感障碍的光疗设备和非成像效应的统一规范:辐射通量。

Towards a uniform specification of light therapy devices for the treatment of affective disorders and use for non-image forming effects: Radiant flux.

机构信息

Chair Building Lighting, Unit Building Physics and Service, Eindhoven University of Technology, The Netherlands.

Chair Building Lighting, Unit Building Physics and Service, Eindhoven University of Technology, The Netherlands.

出版信息

J Affect Disord. 2018 Aug 1;235:142-149. doi: 10.1016/j.jad.2018.04.020. Epub 2018 Apr 5.

Abstract

BACKGROUND

For treating affective disorders like SAD, light therapy is used although the underlying mechanism explaining this success remains unclear. To accelerate the research on defining the light characteristics responsible for inducing a specific effect a uniform manner for specifying the irradiance at the eye should be defined. This allows a genuine comparison between light-affect studies. An important factor impacting the irradiance at the eye are the radiant characteristics of the used light therapy device.

METHOD

In this study the radiant fluxes of five different light therapy devices were measured. The values were weighted against the spectral sensitivity of the five photopigments present in the human eye. A measurement was taken every five minutes to control for a potential stabilizing effect.

RESULTS

The results show that all five devices show large differences in radiant flux. The devices equipped with blue LED lights have a much lower spectral radiant flux than the devices equipped with a fluorescent light source or a white LED. The devices with fluorescent lamps needed 30 min to stabilize to a constant radiant flux.

LIMITATIONS

In this study only five devices were measured. Radiant flux is just the first step to identify uniform specifications for light therapy devices.

CONCLUSIONS

It is recommended to provide all five α-opic radiant fluxes. Preferably, the devices should come with a spectral power distribution of the radiant flux. For the devices equipped with a fluorescent lamp it is recommended to provide information on the stabilization time.

摘要

背景

尽管光照疗法治疗情感障碍(如季节性情感障碍)的潜在机制尚不清楚,但光照疗法仍被用于治疗此类疾病。为了加速研究,明确引发特定效果的光照特性,应采用统一的方法来确定眼部辐照度。这可以实现对光照影响研究的真正比较。影响眼部辐照度的一个重要因素是所使用的光疗设备的辐射特性。

方法

本研究测量了五种不同光疗设备的辐射通量。将这些值与存在于人眼中的五种视色素的光谱灵敏度进行加权。每隔五分钟进行一次测量,以控制潜在的稳定效果。

结果

结果表明,所有五种设备的辐射通量都存在很大差异。配备蓝色 LED 灯的设备的光谱辐射通量远低于配备荧光光源或白色 LED 的设备。配备荧光灯的设备需要 30 分钟才能稳定到恒定的辐射通量。

局限性

本研究仅测量了五种设备。辐射通量只是确定光疗设备统一规格的第一步。

结论

建议提供所有五个α-视场辐射通量。最好设备应提供辐射通量的光谱功率分布。对于配备荧光灯的设备,建议提供关于稳定时间的信息。