在使用米克施源器技术进行永久性前列腺近距离放射治疗期间,使用生物可吸收聚合物涂层减少种子运动。

Reduction of seed motion using a bio-absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique.

作者信息

Warrell Gregory R, Xing Yan, Podder Tarun K, Traughber Bryan J, Ellis Rodney J

机构信息

Department of Radiation Oncology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.

Case Western Reserve University, Cleveland, OH, USA.

出版信息

J Appl Clin Med Phys. 2018 May;19(3):44-51. doi: 10.1002/acm2.12254. Epub 2018 Apr 17.

Abstract

PURPOSE

The addition of a braided bio-absorbable vicryl coating to the surface of radioactive seeds used for low dose rate (LDR) prostate brachytherapy is intended to reduce the incidence of seed movement and migration. Here, we present a single-institution study of the frequency and severity of seed slippage (initial seed movement) of coated seeds in comparison with uncoated seeds.

METHODS

Forty-seven patients received permanent prostate brachytherapy, with either coated (n = 26) or uncoated (n = 21) seeds. AgX100 I seeds, coated or uncoated, and uncoated Model 200 Pd seeds were used. During the ultrasound-guided implantation procedure, each implanted seed was categorized as having remained in the implanted position after being placed, having moved slightly, or having left the ultrasound field of view.

RESULTS

3.1% of the coated seeds (AgX100 seeds, n = 70) and 6.9% of the uncoated seeds (AgX100 and Model 200 seeds, n = 128) were observed to have moved at least 2 mm from their initial implant positions, respectively. The difference in incidence of this movement was 54.4% (P = 0.0026). Coated AgX100 seeds demonstrated a 66.7% lower rate of movement of at least 2 mm than that for uncoated AgX100 seeds (P = 0.038), and a 49.0% lower rate than that for Model 200 seeds (P = 0.021). While no significant differences were noted in prescription dose coverage of the prostate or the studied dosimetric parameters for the organs at risk between the coated and uncoated seeds (P > 0.05) in the CT-based Day-0 postoperative plans, the limited sample size and differences in energies between the I and Pd seeds make further analysis of postoperative dosimetric coverage difficult without additional data directly comparing the coated and uncoated I seeds.

CONCLUSION

When the vicryl coating is used, seeds have a significantly lower propensity to slip from their initial implant locations. This may help maintain dosimetric integrity, warranting further study of postoperative dosimetry.

摘要

目的

在用于低剂量率(LDR)前列腺近距离放射治疗的放射性种子表面添加编织的生物可吸收聚乙醇酸涂层,旨在降低种子移动和迁移的发生率。在此,我们展示了一项单机构研究,比较了有涂层种子与无涂层种子的种子滑动(初始种子移动)频率和严重程度。

方法

47例患者接受了永久性前列腺近距离放射治疗,使用了有涂层(n = 26)或无涂层(n = 21)的种子。使用了有涂层或无涂层的AgX100碘种子以及无涂层的200钯种子。在超声引导的植入过程中,每个植入的种子被分类为放置后仍留在植入位置、稍有移动或离开超声视野。

结果

分别观察到3.1%的有涂层种子(AgX100种子,n = 70)和6.9%的无涂层种子(AgX100和200种子,n = 128)从其初始植入位置移动了至少2毫米。这种移动发生率的差异为54.4%(P = 0.0026)。有涂层的AgX100种子至少移动2毫米的发生率比无涂层的AgX100种子低66.7%(P = 0.038),比200种子低49.0%(P = 0.021)。虽然在基于CT的术后第0天计划中,有涂层和无涂层种子之间前列腺的处方剂量覆盖或危险器官的研究剂量学参数没有显著差异(P > 0.05),但样本量有限以及碘和钯种子之间能量的差异使得在没有直接比较有涂层和无涂层碘种子的额外数据的情况下,对术后剂量学覆盖进行进一步分析变得困难。

结论

使用聚乙醇酸涂层时,种子从其初始植入位置滑落的倾向显著降低。这可能有助于维持剂量学完整性,值得对术后剂量学进行进一步研究。