Suppr超能文献

建立一种多准则决策设计的色谱方法,用于硝苯地平和阿替洛尔在含量均匀度检测中的同时测定。

Development of a chromatographic method with multi-criteria decision making design for simultaneous determination of nifedipine and atenolol in content uniformity testing.

机构信息

Pharmacognosy and Pharmaceutical Chemistry Department, College of Pharmacy Taibah University, Al Madinah AlMunawarah 30001, Saudi Arabia; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt.

Pharmaceutics and Pharmaceutical Technology Department, College of Pharmacy Taibah University, Al Madinah AlMunawarah 30001, Saudi Arabia.

出版信息

Talanta. 2018 Jul 1;184:296-306. doi: 10.1016/j.talanta.2018.03.008. Epub 2018 Mar 7.

Abstract

A new robust and reliable high-performance liquid chromatography (HPLC) method with multi-criteria decision making (MCDM) approach was developed to allow simultaneous quantification of atenolol (ATN) and nifedipine (NFD) in content uniformity testing. Felodipine (FLD) was used as an internal standard (I.S.) in this study. A novel marriage between a new interactive response optimizer and a HPLC method was suggested for multiple response optimizations of target responses. An interactive response optimizer was used as a decision and prediction tool for the optimal settings of target responses, according to specified criteria, based on Derringer's desirability. Four independent variables were considered in this study: Acetonitrile%, buffer pH and concentration along with column temperature. Eight responses were optimized: retention times of ATN, NFD, and FLD, resolutions between ATN/NFD and NFD/FLD, and plate numbers for ATN, NFD, and FLD. Multiple regression analysis was applied in order to scan the influences of the most significant variables for the regression models. The experimental design was set to give minimum retention times, maximum resolution and plate numbers. The interactive response optimizer allowed prediction of optimum conditions according to these criteria with a good composite desirability value of 0.98156. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with the aid of the experimental design. The developed MCDM-HPLC method showed superior robustness and resolution in short analysis time allowing successful simultaneous content uniformity testing of ATN and NFD in marketed capsules. The current work presents an interactive response optimizer as an efficient platform to optimize, predict responses, and validate HPLC methodology with tolerable design space for assay in quality control laboratories.

摘要

一种新的稳健可靠的高效液相色谱(HPLC)方法与多准则决策(MCDM)方法相结合,用于同时定量测定含量均匀度试验中的阿替洛尔(ATN)和硝苯地平(NFD)。在本研究中,非洛地平(FLD)用作内标(IS)。根据 Derringer 的理想性,一种新的交互式响应优化器与 HPLC 方法相结合,用于目标响应的多响应优化。交互式响应优化器被用作根据指定标准,针对目标响应的最佳设置进行决策和预测的工具。在这项研究中考虑了四个独立变量:乙腈%、缓冲液 pH 值和浓度以及柱温。优化了八个响应:ATN、NFD 和 FLD 的保留时间、ATN/NFD 和 NFD/FLD 之间的分辨率以及 ATN、NFD 和 FLD 的板数。应用多元回归分析来扫描对回归模型影响最大的变量。实验设计设定为给出最小保留时间、最大分辨率和板数。交互式响应优化器允许根据这些标准预测最佳条件,复合理想值为 0.98156。在实验设计的帮助下,该方法根据国际协调会议(ICH)指南进行了验证。开发的 MCDM-HPLC 方法在短分析时间内表现出卓越的稳健性和分辨率,允许成功地同时对市售胶囊中的 ATN 和 NFD 进行含量均匀度测试。目前的工作提出了一种交互式响应优化器,作为一种有效的平台,用于优化、预测响应,并验证质量控制实验室含量测定的可接受设计空间的 HPLC 方法。