Aspelin P, Pettersson H, Boijsen E
Department of Diagnostic Radiology, University Hospital, Lund, Sweden.
Acta Radiol. 1988 May-Jun;29(3):277-84.
One hundred consecutive patients were investigated with both a conventional film-screen combination and digital radiography using a laser stimulated luminescence technique in order to evaluate differences in detecting urinary tract stones. All patients were referred either for follow-up of previously known stones or for symptoms. The images were reviewed by two radiologists who had the single clinical information that the patients might have urinary stones. Following review, the two techniques were compared and a consensus was obtained. One hundred and eighteen stones were found in 41 patients without any statistical differences in sensitivity between the two imaging systems.
连续100例患者分别采用传统的屏-片组合成像和使用激光激发发光技术的数字X线摄影进行检查,以评估检测尿路结石的差异。所有患者均因既往已知结石的随访或出现症状而前来就诊。由两位放射科医生对图像进行阅片,他们仅知道患者可能患有尿路结石这一临床信息。阅片后,对两种技术进行比较并达成共识。在41例患者中发现了118颗结石,两种成像系统在敏感性方面无统计学差异。